z-logo
Premium
Practical guidelines for the high‐sensitivity detection and monitoring of paroxysmal nocturnal hemoglobinuria clones by flow cytometry
Author(s) -
Sutherland D. Robert,
Keeney Michael,
Illingworth Andrea
Publication year - 2012
Publication title -
cytometry part b: clinical cytometry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.646
H-Index - 61
eISSN - 1552-4957
pISSN - 1552-4949
DOI - 10.1002/cyto.b.21023
Subject(s) - paroxysmal nocturnal hemoglobinuria , flow cytometry , immunology , medicine , hemoglobinuria , stopped flow , hemolysis , physics , quantum mechanics , reaction rate constant , kinetics
Abstract Background: Paroxysmal nocturnal hemoglobinuria (PNH) is a life‐threatening disorder caused by an inability to make glyco‐phosphatidyl‐inositol (GPI) anchors. While flow cytometry is the method of choice to detect the loss of GPI‐linked proteins, the development and validation of sensitive, standardized, methodologies have been hampered by the rarity of this disease and by technical difficulties in the accurate identification of PNH cells. Methods: Guidelines for the diagnosis and monitoring of PNH by flow cytometry were recently published by the International Clinical Cytometry Society (ICCS). However, specific reagent cocktails, and associated detailed analytic strategies were not directly addressed therein. In this supporting document based on the ICCS guidelines, we provide concise practical protocols for the high‐sensitivity detection of PNH RBCs and WBCs (both granulocytes and monocytes). Results: The CD235aFITC/CD59PE assay described was capable of detecting as few as 20 Type III PNH RBCs per million cells. Frequencies of Type III PNH cells in 10 normal samples were in the 0–6 per million RBCs. The high‐resolution granulocyte/neutrophil assays described in this study could detect PNH phenotypes consistently at a level of 0.01% sensitivity. Frequencies of PNH phenotypes in normal individuals were in the 0–10 per million granulocytes/neutrophils range. Conclusions: The careful screening and selection of specific antibody conjugates has allowed the development of reagent cocktails suitable for high‐sensitivity flow cytometric detection of PNH RBCs and PNH WBCs. The reagent cocktails described herein can be used on a variety of clinical flow cytometers equipped with four or more photo multiplier tubes. © 2012 International Clinical Cytometry Society

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here