z-logo
Premium
Time‐resolved microscopy for imaging lanthanide luminescence in living cells
Author(s) -
Gahlaut Nivriti,
Miller Lawrence W.
Publication year - 2010
Publication title -
cytometry part a
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.316
H-Index - 90
eISSN - 1552-4930
pISSN - 1552-4922
DOI - 10.1002/cyto.a.20964
Subject(s) - autofluorescence , luminescence , microscopy , lanthanide , materials science , fluorescence lifetime imaging microscopy , microscope , luminescent measurements , terbium , fluorescence , fluorescence microscope , optics , europium , optoelectronics , chemistry , physics , ion , organic chemistry
Time‐resolved luminescence (TRL) microscopy can image signals from lanthanide coordination complexes or other probes with long emission lifetimes, thereby eliminating short‐lifetime (<100 ns) autofluorescence background from biological specimens. However, lanthanide complexes emit far fewer photons per unit time than conventional fluorescent probes, making it difficult to rapidly acquire high quality images at probe concentrations that are relevant to live cell experiments. This article describes the development and characterization of a TRL microscope that employs a light‐emitting diode (LED, λ em = 365 nm) for pulsed epi‐illumination and an intensified charge‐coupled device (ICCD) camera for gated, widefield detection. Europium chelate‐impregnated microspheres were used to evaluate instrument performance in terms of short‐lifetime fluorescence background rejection, photon collection efficiency, image contrast, and signal‐to‐noise ratio (SNR). About 200 nm microspheres were imaged within the time resolution limit of the ICCD (66.7 ms) with complete autofluorescence suppression. About 40 nm microspheres containing ∼400 chelate molecules were detected within ∼1‐s acquisition times. A luminescent terbium complex, Lumi4‐Tb®, was introduced into the cytoplasm of cultured cells at an estimated concentration of 300 nM by the method of osmotic lysis of pinocytic vesicles. Time‐resolved images of the living, terbium complex‐loaded cells were acquired within acquisition times as short as 333 ms, and the effects of increased exposure time and frame summing on image contrast and SNR were evaluated. The performance analyses show that TRL microscopy is sufficiently sensitive and precise to allow high‐resolution, quantitative imaging of lanthanide luminescence in living cells under physiologically relevant experimental conditions. © 2010 International Society for Advancement of Cytometry.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here