z-logo
Premium
Flow cytometric method for the assessment of the minimal inhibitory concentrations of antibacterial agents to Mycoplasma agalactiae
Author(s) -
Assunção Patrícia,
Antunes Nuno T.,
Rosales Ruben S.,
de la Fe Christian,
Poveda Carlos,
Poveda José B.,
Davey Hazel M.
Publication year - 2006
Publication title -
cytometry part a
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.316
H-Index - 90
eISSN - 1552-4930
pISSN - 1552-4922
DOI - 10.1002/cyto.a.20331
Subject(s) - tylosin , enrofloxacin , chloramphenicol , microbiology and biotechnology , ciprofloxacin , minimum inhibitory concentration , florfenicol , gentamicin , oxytetracycline , biology , antibacterial agent , streptomycin , flow cytometry , chemistry , antibiotics
In this study, flow cytometry was evaluated for the determination of the minimal inhibitory concentrations (MIC) of seven antibacterial agents (enrofloxacin, ciprofloxacin, gentamicin, streptomycin, chloramphenicol, oxytetracycline, and tylosin) on Mycoplasma (M.) agalactiae . Flow cytometry was able to detect M. agalactiae inhibition from 6 h postincubation, although it seems that definitive MIC values determined by flow cytometry were only possible at 12‐h postincubation. However, the results obtained by the traditional method were only obtained at 24 h, when a visible change in the medium had occurred. At 24 h, both methods gave the same result for six antibacterial agents (enrofloxacin, ciprofloxacin, gentamicin, streptomycin, chloramphenicol, and oxytetracycline); whereas flow cytometry gave slightly higher MIC for tylosin. This was attributed to the fact that the M. agalactiae growth that had occurred in the tubes containing tylosin was not enough to visibly change the color of the medium. Futhermore, flow cytometry detected that inhibitory concentrations of oxytetracycline, chloramphenicol, and tylosin as judged at 24 h were not able to inhibit the M. agalactiae growth after 48 h. MIC values of enrofloxacin and ciprofloxacin were sufficient only to maintain the total counts per milliliter throughout the time matched samples, whereas higher concentrations of theses antibacterial agents reduced the total counts per milliliter over the course of the experiment. The main advantage of the flow cytometric method is that MIC results for M. agalactiae can be obtained in a shorter time than is possible with the traditional method. The method presented makes identification of resistant populations of M. agalactiae possible and, unlike the traditional method, allows the effect of each antibacterial agent to be determined in real‐time at the single‐cell level. © 2006 International Society for Analytical Cytology

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here