z-logo
open-access-imgOpen Access
Accuracy of routine flow‐cytometric bitmap selection for three leukocyte populations
Author(s) -
Sučić Mirna,
Kolevska Tatjana,
Kopjar Branko,
Kosanović Mirjana,
Drobnjak Marija,
Žalud Ivica,
Marušić Matko
Publication year - 1989
Publication title -
cytometry
Language(s) - English
Resource type - Journals
eISSN - 1097-0320
pISSN - 0196-4763
DOI - 10.1002/cyto.990100412
Subject(s) - bitmap , flow cytometry , lymphocyte , granulocyte , monocyte , biology , cell , pathology , microbiology and biotechnology , immunology , medicine , biochemistry , computer science , artificial intelligence
A double‐blind study was performed with peripheral blood of 41 human subjects to check the accuracy of determination of lymphocyte, monocyte, and granulocyte windows with which every flow cytometric analysis of leukocyte markers starts. White blood cell suspensions were prepared according to the whole blood method and analyzed on an EPICS‐C flow cytometer using the two‐parameter 90° light scatter vs. forward angle light scatter (granularity vs. cell size) data distribution. Windows (bitmaps) for lymphocytes, monocytes, and granulocytes were drawn and numbers of cells determined in each. The proportions of lymphocytes, monocytes, and granulocytes were calculated in relation to total cell number, counted and in relation to the sum of cells in three bitmaps, and then compared with proportions determined by microscopic whole blood cell (WBC) differential and a WBC differential determined in an automated hematology analyzer. Average proportions of lymphocytes obtained by the flow cytometer were significantly lower than those obtained by either microscopic or automated differential, suggesting that some of the relevant cells were not included in the bitmaps. Granulocyte proportion related to total cell number was lower and that related to bitmap cell number higher than that obtained by microscopic and automatic differentials, suggesting that nongranulocytic cells were included in the granulocyte bitmaps. Proportions of lymphocytes and granulocytes obtained by the flow cytometer correlated well with those obtained by both microscopic and automatic differential. In contrast, the proportions of monocytes showed a poor correlation, which is probably due to their low number and delicate position in the distribution, and which makes them difficult to delineate.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here