z-logo
Premium
Adequacy evaluation of fine‐needle aspiration biopsy in the breast health clinic setting
Author(s) -
Howell Lydia P.,
GandourEdwards Regina,
Folkins Katherine,
Davis Robin,
Yasmeen Shagufta,
Afify Alaa
Publication year - 2004
Publication title -
cancer cytopathology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 3.052
H-Index - 304
eISSN - 1097-0142
pISSN - 0008-543X
DOI - 10.1002/cncr.20497
Subject(s) - medicine , breast cancer , fine needle aspiration , biopsy , cytopathology , cancer , pathology , cytology
Abstract BACKGROUND Breast health clinics (BHC) are an unfamiliar source of fine‐needle aspiration biopsies (FNABs) in the U.S. and create challenges for adequacy evaluation. The current study described the experience with breast FNAB adequacy evaluation over a 2‐year period, the issues that emerged, and the problem‐solving employed to mitigate these issues. METHODS The rate of unsatisfactory FNABs and core biopsies was determined for pathologists, BHC providers, and other clinicians and compared for two different periods. Adequacy criteria during both periods required correlation of the cytologic findings with the clinical and breast imaging findings, and did not require identification of a specific number of ductal epithelial cells. RESULTS During the first time period, 25% of breast FNABs performed in the BHC received an inadequate evaluation versus 6% performed by pathologists and 14% performed by other clinicians. The BHC adequacy rate exceeded the 20% upper threshold recommended by the National Cancer Institute (NCI), and did not decrease after additional FNAB training. During the first time period, 24% of core biopsies received an adequacy evaluation of unsatisfactory. During the second time interval, the core biopsy volume increased and 12% received an unsatisfactory adequacy evaluation. CONCLUSIONS It is appropriate to use noncellular features such as clinical and imaging findings as adequacy criteria for breast FNABs rather than identification of a minimal number of ductal epithelial cells. However, the 20% upper threshold for unsatisfactory breast FNABs recommended by the NCI was not appropriate for the BHC setting because the nature of the lesions seen in this type of practice can lead to an increase in inadequate specimens and cause unnecessary concern regarding quality. The authors recommended that laboratories receiving a large number of clinician‐performed FNABs from a community population, especially a BHC, define their own unsatisfactory threshold above which they will investigate for technical or other problems. Cancer (Cancer Cytopathol) 2004. © 2004 American Cancer Society.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here