z-logo
open-access-imgOpen Access
High‐throughput screening of chemical exchange saturation transfer MR contrast agents
Author(s) -
Liu Guanshu,
Gilad Assaf A.,
Bulte Jeff W. M.,
van Zijl Peter C. M.,
McMahon Michael T.
Publication year - 2010
Publication title -
contrast media & molecular imaging
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.714
H-Index - 50
eISSN - 1555-4317
pISSN - 1555-4309
DOI - 10.1002/cmmi.383
Subject(s) - saturation (graph theory) , chemistry , diamagnetism , nuclear magnetic resonance , imaging phantom , paramagnetism , analytical chemistry (journal) , spectral line , voxel , quantitative susceptibility mapping , magnetic susceptibility , magnetic field , optics , chromatography , magnetic resonance imaging , physics , computer science , condensed matter physics , artificial intelligence , mathematics , quantum mechanics , combinatorics , astronomy , crystallography , medicine , radiology
Abstract A new high‐throughput MRI method for screening chemical exchange saturation transfer (CEST) agents is demonstrated, allowing simultaneous testing of multiple samples with minimal attention to sample configuration and shimming of the main magnetic field ( B 0 ). This approach, which is applicable to diamagnetic, paramagnetic and liposome CEST agents, employs a set of inexpensive glass or plastic capillary tubes containing CEST agents put together in a cheap plastic tube holder, without the need for liquid between the tubes to reduce magnetic susceptibility effects. In this setup, a reference image of direct water saturation spectra is acquired in order to map the absolute water frequency for each volume element (voxel) in the sample image, followed by an image of saturation transfer spectra to determine the CEST properties. Even though the field over the total sample is very inhomogeneous due to air–tube interfaces, the shape of the direct saturation spectra is not affected, allowing removal of susceptibility shift effects from the CEST data by using the absolute water frequencies from the reference map. As a result, quantitative information such as the mean CEST intensity for each sample can be extracted for multiple CEST agents at once. As an initial application, we demonstrate rapid screening of a library of 16 polypeptides for their CEST properties, but in principle the number of tubes is limited only by the available signal‐noise‐ratio, field of view and gradient strength for imaging. Copyright © 2010 John Wiley & Sons, Ltd.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here