z-logo
open-access-imgOpen Access
Safety and efficacy of second‐generation drug‐eluting stents compared with bare‐metal stents: An updated meta‐analysis and regression of 9 randomized clinical trials
Author(s) -
Mahmoud Ahmed N.,
Shah Nikhil H.,
Elgendy Islam Y.,
Agarwal Nayan,
Elgendy Akram Y.,
Mentias Amgad,
Barakat Amr F.,
Mahtta Dhruv,
David Anderson R.,
Bavry Anthony A.
Publication year - 2018
Publication title -
clinical cardiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.263
H-Index - 72
eISSN - 1932-8737
pISSN - 0160-9289
DOI - 10.1002/clc.22855
Subject(s) - medicine , percutaneous coronary intervention , mace , relative risk , myocardial infarction , confidence interval , surgery , randomized controlled trial , stent , incidence (geometry) , meta analysis , physics , optics
The efficacy of second‐generation drug‐eluting stents (DES; eg, everolimus and zotarolimus) compared with bare‐metal stents (BMS) in patients undergoing percutaneous coronary intervention was challenged recently by new evidence from large clinical trials. Thus, we aimed to conduct an updated systematic review and meta‐analysis of randomized clinical trials (RCTs) evaluating the efficacy and safety of second‐generation DES compared with BMS . Electronic databases were systematically searched for all RCTs comparing second‐generation DES with BMS and reporting clinical outcomes. The primary efficacy outcome was major adverse cardiac events (MACE); the primary safety outcome was definite stent thrombosis. The DerSimonian and Laird method was used for estimation of summary risk ratios (RR). A total of 9 trials involving 17 682 patients were included in the final analysis. Compared with BMS, second‐generation DES were associated with decreased incidence of MACE (RR: 0.78, 95% confidence interval [CI]: 0.69‐0.88), driven by the decreased incidence of myocardial infarction (MI) (RR: 0.67, 95% CI: 0.48‐0.95), target‐lesion revascularization (RR: 0.47, 95% CI: 0.42‐0.53), definite stent thrombosis (RR: 0.57, 95% CI: 0.41‐0.78), and definite/probable stent thrombosis (RR: 0.54, 95% CI: 0.38‐0.80). The incidence of all‐cause mortality was similar between groups (RR: 0.94, 95% CI: 0.79‐1.10). Meta‐regression showed lower incidences of MI with DES implantation in elderly and diabetic patients ( P  = 0.026 and P  < 0.0001, respectively). Compared with BMS, second‐generation DES appear to be associated with a lower incidence of MACE, mainly driven by lower rates of target‐lesion revascularization, MI, and stent thrombosis. However, all‐cause mortality appears similar between groups.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here