z-logo
Premium
Tuning the NiO Thin Film Morphology on Carbon Nanotubes by Atomic Layer Deposition for Enzyme‐Free Glucose Sensing
Author(s) -
Raza Muhammad H.,
Movlaee Kaveh,
Wu Yanlin,
ElRefaei Sayed M.,
Karg Matthias,
Leonardi Salvatore G.,
Neri Giovanni,
Pinicola
Publication year - 2019
Publication title -
chemelectrochem
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.182
H-Index - 59
ISSN - 2196-0216
DOI - 10.1002/celc.201801420
Subject(s) - non blocking i/o , materials science , atomic layer deposition , nanocrystalline material , thin film , transmission electron microscopy , carbon nanotube , chemical engineering , nanotechnology , nanocomposite , layer (electronics) , analytical chemistry (journal) , conformal coating , coating , chemistry , chromatography , organic chemistry , engineering , catalysis
Nanocomposites made of stacked‐cup carbon nanotubes coated with NiO (NiO/SCCNTs) via atomic layer deposition (ALD) were synthesized in order to obtain a material exhibiting enhanced and optimized electrochemical performance towards detections of glucose. The structure and morphology were characterized by transmission electron microscopy (TEM) and X‐ray diffraction (XRD). NiO deposited as nanocrystalline particles in the cubic modification, were well dispersed and directly anchored on SCCNTs forming a smooth particulate thin film, which becomes more dense with the increase of the number of ALD cycles. The NiO/SCCNTs samples with various thicknesses of the NiO coating (0.8 nm, 1.7 nm, 4.0 nm, 6.5 nm, 14.0 nm and 21.8 nm) were applied for enzyme‐free glucose sensing. Their electrochemical performance strongly depends on the thickness of the deposited NiO thin film. The best performing glucose sensors respond over a wide concentration range from 2 μM to 2.2 mM ( R 2 =0.9979) with remarkably enhanced sensitivity (1252.3 μA cm −2  mM −1 ), with a limit of detection (LOD) of 0.10 μM ( S/N =3) and with a fast response time (lower than 2 s). The significant performance improvement can be attributed to the conformal NiO coating, high surface to volume ratio and to the optimized thickness of the NiO thin film. The advantage of our sensors is also associated with the conductive supporting material (SCCNTs), simplicity of fabrication, high sensitivity, selectivity, stability and reproducibility for the rapid quantification of glucose.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here