Subject(s) - paclitaxel , medicine , balloon , plga , angioplasty , biomedical engineering , coating , drug delivery , drug , iopromide , surgery , pharmacology , radiology , chemotherapy , nanoparticle , nanotechnology , materials science , contrast medium
Objectives The aim of this study is to improve local‐drug delivery efficiency and tissue absorption using the ultrasound (US)‐responsible drug coating based on a newly developed US‐controlled paclitaxel release balloon. Background Low availability of the drug coating remains a major concern of the current drug coated balloon (DCB). The goal of this study is to develop a method to use an US‐responsible paclitaxel‐loaded microcapsules (PM) as the main content of balloon drug coating to enhance bioavailability of DCB. Methods An US‐controlled paclitaxel release balloon is designed and fabricated based on the US‐responsible paclitaxel‐loaded poly (lactic‐co‐glycolic acid) (PLGA) microcapsules. Rapid exchange percutaneous transluminal coronary angioplasty (PTCA) balloon catheters were coated with the PM. The deployment processes of the paclitaxel‐loaded microcapsules coated balloons (PMCB) under US, PMCB without US and a homogenous matrix of paclitaxel and iopromide coated balloon (PICB) were then placed in healthy and stent implanted porcine coronary arteries. Results In vitro release assay demonstrated an ability of US (1 MHz, 1.22 W/cm 2 , 1 minute) to affect the release kinetics of paclitaxel from PM by inducing a 76 ± 5.4% increase in the rate of release. The paclitaxel content in target vessels are 203 ± 37 μg/g for PMCB under US, 85 ± 23 μg/g for PMCB without US, and 107 ± 31 μg/g for PICB 1‐hr post‐surgery. The availability of the drug for the PMCB reaches 27% under US. Conclusions The US‐controlled paclitaxel release balloon significantly improved the drug content of the target vessels in the porcine model.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here