Successful percutaneous transcatheter patent foramen ovale closure through the right internal jugular vein using a steerable catheter
Author(s) -
Hascoet Sebastien,
Fraisse Alain,
Elbaz Meyer
Publication year - 2013
Publication title -
catheterization and cardiovascular interventions
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.988
H-Index - 116
eISSN - 1522-726X
pISSN - 1522-1946
DOI - 10.1002/ccd.24868
Subject(s) - medicine , patent foramen ovale , percutaneous , catheter , inferior vena cava filter , internal jugular vein , surgery , cardiology , venous thrombosis , thrombosis
Percutaneous transcatheter closure of a patent foramen ovale (PFO) remains challenging when femoral venous approach is not available. We describe the successful closure of a PFO using the right internal jugular venous approach and a deflectable catheter delivery system in a patient with a PFO, recurrent stroke, and an inferior vena cava filter. © 2013 Wiley Periodicals, Inc.