z-logo
Premium
Percutaneous coronary intervention using a virtual 3‐Fr guiding catheter
Author(s) -
Mizuno Shingo,
Takeshita Satoshi,
Taketani Yoshio,
Saito Shigeru
Publication year - 2010
Publication title -
catheterization and cardiovascular interventions
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.988
H-Index - 116
eISSN - 1522-726X
pISSN - 1522-1946
DOI - 10.1002/ccd.22379
Subject(s) - medicine , conventional pci , percutaneous coronary intervention , angioplasty , radial artery , femoral artery , intravascular ultrasound , catheter , percutaneous , radiology , surgery , artery , coronary artery disease , cardiology , myocardial infarction
Background : We have recently reported a novel percutaneous coronary intervention (PCI) system using a hydrophilic‐coated sheathless guiding catheter (Virtual 3‐Fr, Medikit, Tokyo, Japan), which provides us with less invasive angioplasty and a puncture site injury equivalent to a conventional 3‐Fr introducer sheath. Here, we report the initial results of PCI using this novel system. Methods : A total of 36 coronary artery lesions of 27 patients were treated by using a virtual 3‐Fr PCI system. Procedural outcomes of virtual 3‐Fr PCI were retrospectively evaluated. Results : The mean age was 73.0 ± 8.7 years (range, 46–84 years), and 15 were men (56%). Access sites included the radial artery in 18 patients (67%), the brachial artery in eight patients (30%), and the femoral artery in 1 patients (4%). Among 36 lesions, seven were chronic total occlusions, and a virtual 3‐Fr PCI was successful in 33 lesions (92%). Among the successfully treated 33 lesions, coronary stents were deployed in 32 (97%), and intravascular ultrasound examination was performed in 19 (58%). Hemostasis was achieved immediately after PCIs in all cases. No access‐site related complications including radial artery occlusion were observed. Conclusions : The performance of a virtual 3‐Fr PCI system appears to be comparable to one using a regular 5‐Fr guiding catheter while the puncture‐site damage remains equivalent to that of a 3‐Fr introducer sheath. Virtual 3‐Fr PCI may have a potential to serve as a minimally invasive strategy for the treatment of coronary artery diseases. © 2010 Wiley‐Liss, Inc.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom