Premium
Feasibility and safety of transbrachial approach for patients with severe carotid artery stenosis undergoing stenting
Author(s) -
Wu ChiungJen,
Cheng ChengI,
Hung WeiChin,
Fang ChihYuan,
Yang ChengHsu,
Chen ChienJen,
Chen YenHsun,
Hang ChiLing,
Hsieh YuanKai,
Chen ShyhMing,
Yip HonKan
Publication year - 2006
Publication title -
catheterization and cardiovascular interventions
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.988
H-Index - 116
eISSN - 1522-726X
pISSN - 1522-1946
DOI - 10.1002/ccd.20738
Subject(s) - medicine , catheter , carotid stenting , stenosis , carotid arteries , embolization , radiology , surgery , cardiology , carotid endarterectomy
Although sporadic successful cases using the transradial approach (TRA) for carotid stenting have been reported, the safety and feasibility of carotid stenting using either TRA or a transbrachial approach (TBA) have not been fully investigated. Recently, we have developed a safe and feasible method of TRA for cerebrovascular angiographic studies. This study investigated whether a TBA approach using a 7‐French (F) Kimny guiding catheter for carotid stenting is safe and feasible for patients with severe carotid stenosis. Thirteen patients were enrolled into this study (age range, 63–78 years). Seven of these 13 patients had severe peripheral vascular disease. A retrograde‐engagement technique, involving looping 6‐F Kimny guiding catheter, was utilized for carotid angiographic study. For carotid stenting, the 6‐F Kimny guiding catheter was replaced with a 7‐F Kimny guiding catheter, and the procedure was performed as the follows. First, an extra‐support wire was inserted into the middle portion of external carotid artery (ECA). Second, a 0.035‐inch Teflon wire was advanced into the common carotid artery. Then, the 6‐F guiding catheter was exchanged for a 7‐F Kimny guiding catheter. Third, if the first and second steps did not provide adequate support for exchanging the guiding catheter, a PercuSurge GuardWire™ was inserted into the ECA, followed by distal balloon inflation for an anchoring support. FilterWire EX™ was used in 9 patients and PercuSurge GuardWire in 4 patients to protect from distal embolization during the procedure. The procedure was successful in all patients. No neurological or vascular bleeding complications were observed and all patients were discharged uneventfully. The TBA for carotid stenting was safe and effective, providing a last resort for patients unsuited to femoral arterial access and surgical intervention. © 2006 Wiley‐Liss., Inc.