Premium
Transradial renal angioplasty: Initial experience
Author(s) -
Shuck John,
Khan Amid,
Cavros Nick,
Galanakis Stylianos,
Patel Vishal
Publication year - 2001
Publication title -
catheterization and cardiovascular interventions
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.988
H-Index - 116
eISSN - 1522-726X
pISSN - 1522-1946
DOI - 10.1002/ccd.1297
Subject(s) - medicine , angioplasty , cardiology
We report our early experience of a new technique of renal angioplasty utilizing the radial approach. Certain anatomic considerations continue to make access from above via the arm the preferable approach in selected patients in renal artery stenosis. We have utilized the transradial technique for renal artery angioplasty and stenting successfully in four patients. The development of coronary guidewire (0.014″)‐based peripheral balloons and stent delivery systems has miniaturized equipment sufficiently to make the transradial approach attractive. Present equipment allows for stenting of renal arteries of up to 7 mm with the use of 6 Fr guiding catheters. Present equipment length remains a limitation in taller patients. The transradial approach should be considered in those patients with renal artery or aortoiliac anatomy favoring an approach from the arm. Cathet Cardiovasc Intervent 2001;54:346–349. © 2001 Wiley‐Liss, Inc.