Transcatheter closure of a 16 mm hypertensive patent ductus arteriosus with the Amplatzer muscular VSD occluder
Author(s) -
Demkow Marcin,
Ruzyllo Witold,
Siudalska Hanna,
Kepka Cezary
Publication year - 2001
Publication title -
catheterization and cardiovascular interventions
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.988
H-Index - 116
eISSN - 1522-726X
pISSN - 1522-1946
DOI - 10.1002/ccd.1082
Subject(s) - ductus arteriosus , medicine , cardiology , closure (psychology) , cardiac catheterization , economics , market economy
There is little experience with transcatheter closure of very large, hypertensive patent ductus arteriosus. We present a case of successful closure of a 16 mm ductus with the Amplatzer VSD occluder, a device originally designed for transcatheter closure of congenital muscular ventricular septal defects. To our best knowledge this is the largest ductus ever closed by an interventional technique. Cathet Cardiovasc Intervent 2001;52:359–362. © 2001 Wiley‐Liss, Inc.