z-logo
Premium
Studies on aerosol delivery of plasmid DNA using a mesh nebulizer
Author(s) -
Arulmuthu Eugene R.,
Williams David J.,
Baldascini Helen,
Versteeg Henk K.,
Hoare Mike
Publication year - 2007
Publication title -
biotechnology and bioengineering
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.136
H-Index - 189
eISSN - 1097-0290
pISSN - 0006-3592
DOI - 10.1002/bit.21493
Subject(s) - aerosolization , plasmid , nebulizer , nozzle , chemistry , computational fluid dynamics , aerosol , dna , nanotechnology , materials science , mechanics , biology , inhalation , anatomy , medicine , aerospace engineering , physics , anesthesia , biochemistry , organic chemistry , engineering
Aerosol delivery of plasmid DNA therapeutic solutions is promising for the treatment of respiratory diseases. However, it poses challenges, most significantly the need to protect the delicate supercoiled (sc) structure of plasmid during aerosolization. Nebulizers for liquid aerosolization using meshes appear a better method for delivery than conventional jet and ultrasonic nebulizers. This paper explores their application to the delivery of plasmid DNA. A computational fluid dynamics model of the dynamics of fluid flow through the nozzle of the MicroAIR® mesh nebulizer indicated high strain rates (>10 5 s −1 ) near the nozzle exit capable of causing damage to the shear‐sensitive plasmid DNA. Knowledge of the strain rates predicted using CFD and molecule size determined using atomic force microscopy (AFM) enabled estimation of the hydrodynamic force and whether damage of shear‐sensitive therapeutics was likely. Plasmids of size 5.7 and 20 kb were aerosolized in the mesh nebulizer. The sc structure of the 5.7‐kb plasmid was successfully delivered without damage, while aerosolization of the 20‐kb plasmid led to disintegration of the pDNA sc structure as observed in AFM. Subsequent formulation of the sc 20‐kb plasmid with PEI resulted in successful aerosol delivery. The maximum hydrodynamic forces computed for the aerosolization of structures of the size of 5.7‐kb and PEI formulated 20‐kb plasmids were less than the forces reported to damage the structure of double‐stranded DNA. A combination of CFD analysis and structure analysis may be used to predict successful aerosol delivery in such a mesh nebulizer. Biotechnol. Bioeng. 2007;98: 939–955. © 2007 Wiley Periodicals, Inc.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom