z-logo
Premium
Peptide‐polymer biotherapeutic synthesis on novel cross‐linked beads with “spatially tunable” and “isolated” functional sites
Author(s) -
Jacob M. K.,
Leena S.,
Kumar K. S.
Publication year - 2008
Publication title -
peptide science
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.556
H-Index - 125
eISSN - 1097-0282
pISSN - 0006-3525
DOI - 10.1002/bip.20969
Subject(s) - chemistry , peptide , polymer , combinatorial chemistry , biophysics , nanotechnology , biochemistry , organic chemistry , materials science , biology
Abstract Solid phase synthesis of polymer biotherapeutics using conventional polymers suffers from many limitations such as low synthetic yield and purity. The conventional polymers prepared by either pre‐ or post‐functionalization strategies have no control over the point of functionalization. Hence we report a novel cross‐linked polymer in which the functional groups are spatially tuned to predefined distance with optimal site isolation. This has been achieved by the design and synthesis of a tetra functional PEG, 3,3′‐(PEG)bis(1‐(4‐vinylphenoxy)propan‐2‐ol) (bis(VPP)PEG). It has been incorporated at cross‐linking of 1–12%, into a polystyrene network by free radical suspension polymerization. In this polymer, the distance between hydroxyl functional groups has been spatially tuned in a predefined manner by varying the length of the cross‐linker backbone from ethylene glycol to PEG 1000 Da and the loading capacity could be varied from 0.1 to 0.9 mmol/g. The polymer has been characterized by SEM, FTIR, and 13 C NMR. The polymer exhibits excellent swelling behavior and high chemical stability. The synthetic efficiency of the polymer was demonstrated by the successful synthesis of three structural classes of PEGylated antimicrobial peptide biotherapeutics and the difficult ACP (65–74) fragment. Thus the “spatially defined” and “site isolated” synthesis within the new polymer offers a novel strategy for synthesis of difficult peptide‐polymer bioconjugates. The bioassay studies shows that PEGylation of AMPs significantly reduces their hemolytic potential but the retainment of antibacterial property was dependent both on the peptide sequence and the size of PEG used. © 2008 Wiley Periodicals, Inc. Biopolymers (Pept Sci) 90: 512–525, 2008. This article was originally published online as an accepted preprint. The “Published Online” date corresponds to the preprint version. You can request a copy of the preprint by emailing the Biopolymers editorial office at biopolymers@wiley.com

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here