z-logo
Premium
Investigation of the bioactivity and biocompatibility of different glass interfaces with hydroxyapatite, fluorohydroxyapatite and 58S bioactive glass
Author(s) -
Han Yuling Jamie,
Loo Say Chye Joachim,
Lee Joel,
Ma Jan
Publication year - 2007
Publication title -
biofactors
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.204
H-Index - 94
eISSN - 1872-8081
pISSN - 0951-6433
DOI - 10.1002/biof.5520300402
Subject(s) - bioactive glass , biocompatibility , materials science , simulated body fluid , coating , chemical engineering , substrate (aquarium) , scanning electron microscope , layer (electronics) , composite material , thin film , nanotechnology , metallurgy , oceanography , engineering , geology
The current review investigates the bioactivity of different glass interfaces created on thin glass cover slips as substrates. The interfaces studied are plain glass, functionalized glass using 0.5 M and 5 M of sodium hydroxide (NaOH) for 24 hrs, and glass coated with bioactive 58S Bioglass (58S). A biomimetic method, involving the exposure of the three interfaces to 1.5 times simulated body fluid (SBF) tests the bioactivity of the interfaces via creation of layer of Hydroxyapatite (HA). Fluorinated SBF will precipitate fluorine doped HA (FHA) on a bioactive interface. Higher concentration of 1.5 times of SBF used in this study intended to accelerate the formation of HA and FHA layer over the substrate. HA and FHA is found to be precipitated on the thinly coated 58S. This paper, study also the thin film coatings of three forms of bioceramics — bioactive 58S, HA and FHA. The study, also proposes to draw a relation between the morphology of HA particles with duration of exposure to SBF, the effects of fluorine on the morphology and the cell interaction with bioactive 58S, HA and FHA interfaces using pre‐differentiated osteoblastic MC3T3 cells. The analysis of cells in this study is confined to three parameters that include the attachment, proliferation and viability of cells. Tests employed for the analysis of the thin film coating of HA and FHA is restricted to qualitative X‐Ray Diffraction and quantitative Field Emission Scanning Electron Microscope. Other mechanical tests such as shear test are not used to test the mechanical properties of this thin layer, due to the fact that the thin film is too thin for such analysis.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here