Influence of 50 Hz electric and magnetic fields on the human heart
Author(s) -
Korpinen L.,
Partanen J.,
Uusitalo A.
Publication year - 1993
Publication title -
bioelectromagnetics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.435
H-Index - 81
eISSN - 1521-186X
pISSN - 0197-8462
DOI - 10.1002/bem.2250140405
Subject(s) - electric field , human heart , magnetic field , heart rate , cardiology , medicine , nuclear magnetic resonance , physics , quantum mechanics , blood pressure
Abstract This investigation studied the effect of 50 Hz electric and magnetic fields on the human heart. The electrocardiograms of 27 transmission‐line workers and 26 male volunteers were recorded with a Holter recorder both in and outside the fields. The measurements took from half an hour to a few hours. The electric field strength varied from 0.14 to 10.21 kV/m and the magnetic flux density from 1.02 to 15.43 μT. Analysis of the ECG recordings showed that extrasystoles or arrhythmias were as frequent outside the field as in the field. In some cases a small decrease in heart rate was observed after field exposure. © 1993 Wiley‐Liss, Inc.