Premium
Control of energy absorption rate in transmission line radiofrequency exposure systems
Author(s) -
Ali Joseph S.,
Elliott Dorothy J.
Publication year - 1987
Publication title -
bioelectromagnetics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.435
H-Index - 81
eISSN - 1521-186X
pISSN - 0197-8462
DOI - 10.1002/bem.2250080207
Subject(s) - absorption (acoustics) , energy (signal processing) , transmission (telecommunications) , specific absorption rate , materials science , environmental science , nuclear engineering , physics , optics , computer science , telecommunications , engineering , quantum mechanics , antenna (radio)
A frequent problem in the radiofrequency (RF) irradiation of experimental animals in health effects studies is the temporal variation of the specific absorption rate (SAR) with animal movement. An RF power controller that regulates the energy absorption rate has been designed for use with transmission line exposure systems that utilize the power difference method to monitor the SAR. The controller operates by altering the incident power to the exposure cell in order to compensate for the change in RF energy absorption rate that is due to animal motion. A circuit diagram is presented as well as experimental data under three conditions of exposure. The controller is effective in maintaining the mean value of energy absorption rate at the setpoint value even for the case of a highly active animal.