Interference of programmed electromagnetic stimulation with pacemakers and automatic implantable cardioverter defibrillators
Author(s) -
Gwechenberger Marianne,
Rauscha Friedrich,
Stix Günter,
Schmid Gernot,
StrametzJuranek Jeanette
Publication year - 2006
Publication title -
bioelectromagnetics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.435
H-Index - 81
eISSN - 1521-186X
pISSN - 0197-8462
DOI - 10.1002/bem.20217
Subject(s) - torso , biomedical engineering , electromagnetic interference , interference (communication) , implant , signal (programming language) , induction coil , bar (unit) , electrode , medicine , materials science , acoustics , electrical engineering , electromagnetic coil , surgery , engineering , computer science , physics , channel (broadcasting) , meteorology , anatomy , programming language , quantum mechanics
Abstract A commercially available magnetic therapy system, designed for clinical application as well as for private use without medical supervision, was examined with respect to its potential for causing electromagnetic interference with implantable pacemakers (PMs) and automatic implantable cardioverter defibrillators (AICDs). A sample of 15 PMs and 5 AICDs were experimentally investigated. Each of the implants was realistically positioned in a homogeneous, electrically passive torso phantom and exposed to the magnetic fields of the system's applicators (whole body mat, cushion, and bar applicator). The detection thresholds of the implants were programmed to maximum sensitivity and both unipolar as well as bipolar electrode configurations were considered. The evaluation of possible interferences was derived from the internal event storages and pacing statistics recorded by the implants during exposure. Any “heart activity” recorded by the implants during exposure was interpreted as a potential interference, because the implant obviously misinterpreted the external interference signal as a physiological signal. Only cases without any recorded “heart activity” and with nominal pacing rates (as expected from the program parameter settings) of the implants were rated as “interference‐free.” Exposure to the whole body mat (peak magnetic induction up to 265 µT) did not show an influence on PMs and AICD in any case. The cushion applicator at the highest field intensity (peak magnetic induction up to 360 µT) led to atrial sensing defects in four PM models with unipolar electrode configuration. Under bipolar electrode configuration no disturbances occurred. The bar applicator led to sensing problems and consecutively reduced pacing rates in all tested PM models under unipolar electrode configuration and maximum field intensity (peak magnetic induction up to 980 µT). Bipolar electrode configuration resolved the problem. The investigated AICDs did not show malfunctions under any investigated condition. In conclusion, the examined PEMF therapy system did not interfere with the investigated implantable cardiac devices with bipolar electrode configuration. However, unipolar electrode configuration in pacemakers seems to be potentially hazardous during application of the examined PEMF therapy system. Bioelectromagnetics 27:365–377, 2006. © 2006 Wiley‐Liss, Inc.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here