Premium
Different Mismatch Concepts for Magnetic Resonance Imaging–Guided Thrombolysis in Unknown Onset Stroke
Author(s) -
Scheldeman Lauranne,
Wouters Anke,
Boutitie Florent,
Dupont Patrick,
Christensen Soren,
Cheng Bastian,
Ebinger Martin,
Endres Matthias,
Fiebach Jochen B.,
Gerloff Christian,
Muir Keith W.,
Nighoghossian Norbert,
Pedraza Salvador,
Simonsen Claus Z.,
Thijs Vincent,
Thomalla Götz,
Lemmens Robin
Publication year - 2020
Publication title -
annals of neurology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 4.764
H-Index - 296
eISSN - 1531-8249
pISSN - 0364-5134
DOI - 10.1002/ana.25730
Subject(s) - fluid attenuated inversion recovery , medicine , magnetic resonance imaging , thrombolysis , modified rankin scale , stroke (engine) , confidence interval , nuclear medicine , radiology , diffusion mri , ischemic stroke , ischemia , mechanical engineering , myocardial infarction , engineering
Objective To explore the prevalence of the perfusion‐weighted imaging (PWI)–diffusion‐weighted imaging (DWI) mismatch and response to intravenous thrombolysis in the WAKE‐UP trial. Methods We performed a prespecified post hoc analysis of ischemic stroke patients screened for DWI–fluid‐attenuated inversion recovery (FLAIR) mismatch in WAKE‐UP who underwent PWI. We defined PWI‐DWI mismatch as ischemic core volume < 70ml, mismatch volume > 10ml, and mismatch ratio > 1.2. Primary efficacy end point was a modified Rankin Scale score of 0–1 at 90 days, adjusted for age and symptom severity. Results Of 1,362 magnetic resonance imaging–screened patients, 431 underwent PWI. Of these, 57 (13%) had a double mismatch, 151 (35%) only a DWI‐FLAIR mismatch, and 54 (13%) only a PWI‐DWI mismatch. DWI‐FLAIR mismatch was more prevalent than PWI‐DWI mismatch (48%, 95% confidence interval [CI] = 43–53% vs 26%, 95% CI = 22–30%; p < 0.0001). Screening for either one of the mismatch profiles resulted in a yield of 61% (95% CI = 56–65%). Prevalence of PWI‐DWI mismatch was similar in patients with (27%) or without (24%) DWI‐FLAIR mismatch ( p = 0.52). In an exploratory analysis in the small subgroup of 208 randomized patients with PWI, PWI‐DWI mismatch status did not modify the treatment response ( p for interaction = 0.73). Interpretation Evaluating both the DWI‐FLAIR and PWI‐DWI mismatch patterns in patients with unknown time of stroke onset will result in the highest yield of thrombolysis treatment. The treatment benefit of alteplase in patients with a DWI‐FLAIR mismatch seems to be driven not merely by the presence of a PWI‐DWI mismatch, although this analysis was underpowered. ANN NEUROL 2020;87:931–938