Premium
Pet Groomer's Lung: A novel occupation related hypersensitivity pneumonitis related to pyrethrin exposure in a pet groomer
Author(s) -
Pu Chan Yeu,
Rasheed Mohamed Rizwan Haroon Al,
Sekosan Marin,
Sharma Vibhu
Publication year - 2017
Publication title -
american journal of industrial medicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.7
H-Index - 104
eISSN - 1097-0274
pISSN - 0271-3586
DOI - 10.1002/ajim.22664
Subject(s) - medicine , hypersensitivity pneumonitis , lung , toxicology , biology
A 61‐year‐old man was evaluated for a 2 month history of cough and dyspnea without relevant exposures other than pyrethrin containing insecticidal sprays he used while grooming dogs almost daily. High Resolution Computed Tomography (HRCT) of the chest demonstrated a Non‐Specific Interstitial Pneumonia (NSIP) pattern. Pulmonary function testing revealed an isolated mildly reduced diffusion capacity. Bronchoalveolar lavage (BAL) results confirmed the presence of foamy histiocytes, lymphocytes, and polymorphonuclear cells consistent with ongoing exposure. Open lung biopsy showed poorly formed granulomas and bronchiolitis. He was advised to avoid exposure to pyrethrin. While he declined to stop grooming dogs, on follow‐up, his symptoms had improved with use of a P100 mask and better ventilation to protect himself when using the pet sprays. We conclude that sustained exposure to pyrethrin containing sprays in the pet grooming industry may be a risk factor for a novel occupation related hypersensitivity pneumonitis. (“Pet Groomer's Lung”). Am. J. Ind. Med. 60:141–145, 2017. © 2016 Wiley Periodicals, Inc.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom