Heat transfer in liquid‐liquid spray towers
Author(s) -
Greskovich E. J.,
Barton Paul,
Hersh R. E.
Publication year - 1967
Publication title -
aiche journal
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.958
H-Index - 167
eISSN - 1547-5905
pISSN - 0001-1541
DOI - 10.1002/aic.690130623
Subject(s) - kerosene , heat transfer , thermodynamics , boiling point , heat transfer coefficient , distributor , boiling , materials science , chemistry , range (aeronautics) , mechanics , analytical chemistry (journal) , composite material , chromatography , physics
An experimental investigation of heat transfer rates in which were used three spray towers varying from 4 to 6 in. in diameter and 7 to 10 ft. in height, and distributor elements with hole sizes varying from 1/8 to 1/64 in. in diameter was carried out. The immiscible liquid system consisted of water and kerosene (normal boiling point range 395° to 490°F.). Volumetric heat transfer coefficients ranged from 100 to 3,600 B.t.u./(hr.)(cu. ft.)(°F.) and the overall film heat transfer coefficients ranged from 4 to 23 B.t.u./(hr.)(sq. ft.)(°F.). Height equivalent to a theoretical stage varied from 1 to 8 ft. Scale‐up correlations relating these rate data to operating variables were developed.