z-logo
Premium
Air pollution remediation in a fixed bed photocatalytic reactor coated with TiO 2
Author(s) -
Esterkin C. R.,
Negro A. C.,
Alfano O. M.,
Cassano A. E.
Publication year - 2005
Publication title -
aiche journal
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.958
H-Index - 167
eISSN - 1547-5905
pISSN - 0001-1541
DOI - 10.1002/aic.10472
Subject(s) - photocatalysis , chemistry , reaction rate , kinetic energy , irradiation , catalysis , relative humidity , thermodynamics , physics , organic chemistry , quantum mechanics , nuclear physics
In a previous article, the modeling and experimental verification of the radiation field inside a reactor made of several TiO 2 coated, parallel, flat glass fiber meshes, bilaterally UV irradiated was accomplished. The degradation of trichloroethylene (TCE) in an air stream is studied using different values of the pollutant feed concentration, relative humidity and light intensity under operating conditions where kinetic control of the process is established. A kinetic model based on a reaction scheme that involves atomic chlorine as an active reaction intermediate is developed for describing concentration dependencies. It includes, explicitly, the effect of the absorbed light intensity on the rate. The interaction of the existing radiation field with the solid semiconductor to generate electrons, and holes in the reaction catalyst activation step is also modeled. All kinetic parameters are estimated from experiments. The obtained kinetic expression gives a first‐order dependence with respect to the TCE concentration and accounts for a competitive effect of water vapor and TCE for the catalyst active sites. An additional important feature of the derived expression is its ability to represent both limiting cases concerning the dependence of the reaction rate with the irradiation rate; that is, order 1 or order 0.5, as well as all possible intermediate values. In fact, the equivalent dependence obtained in this work was 0.6, a value closer to the second case. The results show good agreement between predictions derived from the proposed kinetic expression and TCE experimental concentration data at the reactor's exit. The proposed reactor design provides a practical device for the treatment of contaminated air; it permits a fairly uniform irradiation of the catalytic meshes and a good ratio of the irradiated surface area with respect to the volume of the gaseous reacting mixture. With these features, rather high TCE conversions can be obtained. © 2005 American Institute of Chemical Engineers AIChE J, 2005

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here