Development of an anthropomorphic multimodality pelvic phantom for quantitative evaluation of a deep‐learning‐based synthetic computed tomography generation technique
Author(s) -
Jin Hyeongmin,
Lee Sung Young,
An Hyun Joon,
Choi Chang Heon,
Chie Eui Kyu,
Wu HongGyun,
Park Jong Min,
Park Sukwon,
Kim Jungin
Publication year - 2022
Publication title -
journal of applied clinical medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.83
H-Index - 48
ISSN - 1526-9914
DOI - 10.1002/acm2.13644
Subject(s) - imaging phantom , multimodality , computed tomography , deep learning , medical physics , computer science , artificial intelligence , nuclear medicine , radiology , medicine , world wide web
Purpose The objective of this study was to fabricate an anthropomorphic multimodality pelvic phantom to evaluate a deep‐learning‐based synthetic computed tomography (CT) algorithm for magnetic resonance (MR)‐only radiotherapy. Methods Polyurethane‐based and silicone‐based materials with various silicone oil concentrations were scanned using 0.35 T MR and CT scanner to determine the tissue surrogate. Five tissue surrogates were determined by comparing the organ intensity with patient CT and MR images. Patient‐specific organ modeling for three‐dimensional printing was performed by manually delineating the structures of interest. The phantom was finally fabricated by casting materials for each structure. For the quantitative evaluation, the mean and standard deviations were measured within the regions of interest on the MR, simulation CT (CT sim ), and synthetic CT (CT syn ) images. Intensity‐modulated radiation therapy plans were generated to assess the impact of different electron density assignments on plan quality using CT sim and CT syn . The dose calculation accuracy was investigated in terms of gamma analysis and dose‐volume histogram parameters. Results For the prostate site, the mean MR intensities for the patient and phantom were 78.1 ± 13.8 and 86.5 ± 19.3, respectively. The mean intensity of the synthetic image was 30.9 Hounsfield unit (HU), which was comparable to that of the real CT phantom image. The original and synthetic CT intensities of the fat tissue in the phantom were −105.8 ± 4.9 HU and −107.8 ± 7.8 HU, respectively. For the target volume, the difference in D 95% was 0.32 Gy using CT syn with respect to CT sim values. The V 65Gy values for the bladder in the plans using CT sim and CT syn were 0.31% and 0.15%, respectively. Conclusion This work demonstrated that the anthropomorphic phantom was physiologically and geometrically similar to the patient organs and was employed to quantitatively evaluate the deep‐learning‐based synthetic CT algorithm.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here