Comparison of treatment plans for hypofractionated high‐dose prostate cancer radiotherapy using the Varian Halcyon and the Elekta Synergy platforms
Author(s) -
Tamihardja Jörg,
Razinskas Gary,
Exner Florian,
Richter Anne,
Kessler Patrick,
Weick Stefan,
Kraft Johannes,
Mantel Frederick,
Flentje Michael,
Polat Bülent
Publication year - 2021
Publication title -
journal of applied clinical medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.83
H-Index - 48
ISSN - 1526-9914
DOI - 10.1002/acm2.13380
Subject(s) - quality assurance , medicine , nuclear medicine , dosimetry , radiation therapy , radiation treatment planning , tomotherapy , prostate cancer , prostate , linear particle accelerator , medical physics , radiology , cancer , physics , external quality assessment , pathology , optics , beam (structure)
Purpose To compare radiotherapy plans between an O‐ring and a conventional C‐arm linac for hypofractionated high‐dose prostate radiotherapy in terms of plan quality, dose distribution, and quality assurance in a multi‐vendor environment. Methods Twenty prostate cancer treatment plans were irradiated on the O‐ring Varian Halcyon linac and were re‐optimized for the C‐arm Elekta Synergy Agility linac. Dose‐volume histogram metrics for target coverage and organ at risk dose, quality assurance, and monitor units were retrospectively compared. Patient‐specific quality assurance with ion chamber measurements, gamma index analysis, and portal dosimetry was performed using the Varian Portal Dosimetry system and the ArcCHECK ® phantom (Sun Nuclear Corporation). Prostate‐only radiotherapy was delivered with simultaneous integrated boost (SIB) volumetric modulated arc therapy (VMAT) in 20 fractions of 2.5/3.0 Gy each. Results For both linacs, target coverage was excellent and plan quality comparable. Homogeneity in PTV Boost was high for Synergy as well as Halcyon with a mean homogeneity index of 0.07 ± 0.01 and 0.05 ± 0.01, respectively. Mean dose for the organs at risk rectum and bladder differed not significantly between the linacs but were higher for the femoral heads and penile bulb for Halcyon. Quality assurance showed no significant differences in terms of ArcCHECK gamma pass rates. Median pass rate for 3%/2 mm was 99.3% (96.7 to 99.8%) for Synergy and 99.8% (95.6 to 100%) for Halcyon. Agreement between calculated and measured dose was high with a median deviation of −0.6% (−1.7 to 0.8%) for Synergy and 0.2% (−0.6 to 2.3%) for Halcyon. Monitor units were higher for the Halcyon by approximately 20% ( p  < 0.001). Conclusion Hypofractionated high‐dose prostate cancer SIB VMAT on the Halcyon system is feasible with comparable plan quality in reference to a standard C‐arm Elekta Synergy linac.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here