Cleaning the dose falloff in lung SBRT plan
Author(s) -
Desai Dharmin,
Narayanasamy Ganesh,
Bimali Milan,
Cordrey Ivan,
Elasmar Hisham,
Srinivasan Senthamizhchelvan,
Johnson Ellis Lee
Publication year - 2021
Publication title -
journal of applied clinical medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.83
H-Index - 48
ISSN - 1526-9914
DOI - 10.1002/acm2.13113
Subject(s) - nuclear medicine , wilcoxon signed rank test , medicine , lung , mathematics , mann–whitney u test
Purpose To investigate a planning technique that can possibly reduce low‐to‐intermediate dose spillage (measured by R50%, D2cm values) in lung SBRT plans. Materials and Methods Dose falloff outside the target was studied retrospectively in 102 SBRT VMAT plans of lung tumor. Plans having R50% and/or D2cm higher than recommended tolerances in RTOG protocols 0813 and 0915 were replanned with new optimization constraints using novel shell structures and novel constraints. Violations in the RTOG R50% value can be rectified with a dose constraint to a novel shell structure (“OptiForR50”). The construction of structure OptiForR50% and the novel optimization criteria translate the RTOG goals for R50% into direct inputs for the optimizer. Violations in the D2cm can be rectified using constraints on a 0.5 cm thick shell structure with inner surface 2cm from the PTV surface. Wilcoxon signed‐rank test was used to compare differences in dose conformity, volume of hot spots, R50%, D2cm of the target in addition to the OAR doses. A two‐sided P ‐value of 0.05 was used to assess statistical significance. Results Among 102 lung SBRT plans with PTV sizes ranging from 5 to 179 cc, 32 plans with violations in R50% or D2cm were reoptimized. The mean reduction in R50% (4.68 vs 3.89) and D2cm (56.49 vs 52.51) was statistically significant both having P  < 0.01. Target conformity index, volume of 105% isodose contour outside PTV, normal lung V20, and mean dose to heart and aorta were significantly lowered with P  < 0.05. Conclusion The novel planning methodology using multiple shells including the novel OptiForR50 shell with precisely calculated dimensions and optimizer constraints lead to significantly lower values of R50% and D2cm and lower dose spillage in lung SBRT plans. All plans were successfully brought into the zone of no RTOG violations.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here