Clinical acceptance testing and scanner comparison of ultrasound shear wave elastography
Author(s) -
Long Zaiyang,
Tradup Donald J.,
Song Pengfei,
Stekel Scott F.,
Chen Shigao,
Glazebrook Katri.,
Hangiandreou Nicholas J.
Publication year - 2018
Publication title -
journal of applied clinical medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.83
H-Index - 48
ISSN - 1526-9914
DOI - 10.1002/acm2.12310
Subject(s) - imaging phantom , scanner , standard deviation , transducer , ultrasound , acoustics , biomedical engineering , nuclear medicine , materials science , medical physics , physics , medicine , mathematics , optics , statistics
Because of the rapidly growing use of ultrasound shear wave elastography ( SWE ) in clinical practices, there is a significant need for development of clinical physics performance assessment methods for this technology. This study aims to report two clinical medical physicists’ tasks: (a) acceptance testing ( AT ) of SWE function on ten commercial ultrasound systems for clinical liver application and (b) comparison of SWE measurements of targets across vendors for clinical musculoskeletal application. For AT , ten GE LOGIQ E9 XD clear 2.0 scanners with ten C1‐6‐D and ten 9L‐D transducers were studied using two commercial homogenous phantoms. Five measurements were acquired at two depths for each scanner/transducer pair by two operators. Additional tests were performed to access effects of different coupling media, phantom locations and operators. System deviations were less than 5% of group mean or three times standard deviation; therefore, all systems passed AT . A test protocol was provided based on results that no statistically significant difference was observed between using ultrasound gel and salt water for coupling, among different phantom locations, and that interoperator and intraoperator coefficient of variation was less than 3%. For SWE target measurements, two systems were compared — a Supersonic Aixplorer scanner with a SL 10‐2 and a SL 15‐4 transducer, and an abovementioned GE scanner with 9L‐D transducer. Two stepped cylinders with diameters of 4.05–10.40 mm were measured both longitudinally and transaxially. Target shear wave speed quantification was performed using an in‐house MATLAB program. Using the target shear wave speed deduced from phantom specs as a reference, SL 15‐4 performed the best at the measured depth. However, it was challenging to reliably measure a 4.05 mm target for either system. The reported test methods and results could provide important information when dealing with SWE ‐related tasks in the clinical environment.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here