Development of a novel low‐radiation‐absorbent lok‐bar to reduce X‐ray scattering and absorption in RapidArc ® treatment planning and dose delivery
Author(s) -
Monzen Hajime,
Kubo Kazuki,
Tamura Mikoto,
Hayakawa Masaru,
Nishimura Yasumasa
Publication year - 2017
Publication title -
journal of applied clinical medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.83
H-Index - 48
ISSN - 1526-9914
DOI - 10.1002/acm2.12066
Subject(s) - bar (unit) , attenuation , nuclear medicine , materials science , imaging phantom , x ray , dosimetry , radiation , scattering , absorption (acoustics) , physics , optics , medicine , meteorology
We developed a novel low‐radiation‐absorbent lok‐bar ( HM ‐bar) that is used to secure the immobilizers to the couch. The aim of this study was to investigate the X‐ray scattering and absorption properties of the HM ‐bar in computed tomography ( CT ) simulation and radiotherapy dose delivery using the Varian Exact™ lok‐bar ( VL ‐bar) as a benchmark. CT images were obtained with or without lok‐bar, and then each image was visually evaluated for artifacts. The attenuation rates for each lok‐bar were measured using a farmer‐type ionization chamber ( PTW 30013) and the I'm RT phantom ( IBA Dosimetry GmbH). Measurement points were between gantry angles of 110 and 180°. The treatment apparatus was a NovalisTx (Brainlab AG ); X‐ray energies were set at 6  MV and 10  MV . In the presence of each lok‐bar, the radiation dose was measured in accordance with 10 volumetric modulated arc therapy–stereotactic body radiation therapy ( VMAT ‐ SBRT ) plans for lung cancer. Artifacts were seldom observed in the CT scans of the HM ‐bar. The attenuation rate of each lok‐bar was higher when the X‐ray energy was set at 6  MV than at 10  MV . The highest attenuation rate in the VL ‐bar was observed at a gantry angle of 112°; the rates were 22.4% at 6  MV and 19.3% at 10  MV . Similarly, the highest attenuation rate for the HM ‐bar was also observed at a gantry angle of 112°; the rates were 12.2% and 10.1% at 6  MV and 10  MV , respectively. When the VL ‐bar was evaluated, the isocenter dose of the VMAT ‐ SBRT plans was attenuated by 2.6% as a maximum case. In the case of the HM ‐bar, the maximum attenuation was 1.4%. In the measurements of each VMAT ‐ SBRT plan, the difference of the dose attenuation rate between the VL ‐bar and HM ‐bar was approximately 1%. The HM ‐bar could be used to minimize the occurrence of artifacts and provide good images in CT scans regarding radiotherapy planning and dose calculation. It can be used for patient therapy at hospitals to provide accurate dose delivery because of its low X‐ray scattering and absorption characteristics.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here