z-logo
Premium
Late coil migration due to thrombolysis after successful implantation of a coil for persistent ductus arteriosus
Author(s) -
Huang TaCheng,
Hsieh KaiSheng,
Lee ChengLiang
Publication year - 2000
Publication title -
catheterization and cardiovascular interventions
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.988
H-Index - 116
eISSN - 1522-726X
pISSN - 1522-1946
DOI - 10.1002/1522-726x(200007)50:3<334::aid-ccd13>3.0.co;2-m
Subject(s) - medicine , ductus arteriosus , electromagnetic coil , thrombus , thrombolysis , shunt (medical) , cardiology , complication , surgery , myocardial infarction , electrical engineering , engineering
Transcatheter coil occlusion of persistent ductus arteriosus (PDA) is now a widely accepted treatment for PDA. However, late complication might occur due to thrombolytic treatment during the interventional period. We discuss a case with late coil migration due to thrombolysis after successful implantation of a coil. It should be emphasized that early thrombus formation is important for successful closure of PDA shunt using coil. Cathet. Cardiovasc. Intervent. 50:334–336, 2000. © 2000 Wiley‐Liss, Inc.