z-logo
Premium
A quantitative analysis of cortical spreading depression events in the feline brain characterized with diffusion‐weighted MRI
Author(s) -
Bockhorst K.H.J.,
Smith J.M.,
Smith M.I.,
Bradley D.P.,
Houston G.C.,
Carpenter T.A,
Hall L.D.,
Papadakis N.G.,
Parsons A.A.,
Huang C.L.H.,
James M.F.
Publication year - 2000
Publication title -
journal of magnetic resonance imaging
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.563
H-Index - 160
eISSN - 1522-2586
pISSN - 1053-1807
DOI - 10.1002/1522-2586(200011)12:5<722::aid-jmri9>3.0.co;2-a
Subject(s) - gyrus , cortical spreading depression , nuclear medicine , diffusion mri , nuclear magnetic resonance , magnetic resonance imaging , medicine , physics , radiology , migraine
Cortical spreading depression (CSD) in the gyrencephalic cat brain was detected with diffusion‐weighted echoplanar (DWEP) magnetic resonance imaging (4–8/min for 1–2 hours) using a horizontal imaging plane through the suprasylvian (SG) and marginal gyri. A t ‐statistic mapping technique allowed a quantitative characterization of the passage of events through single‐image pixels (0.15 mm 2 ), thus providing a resolution unavailable to previous studies in which time‐dependent changes instead were derived from averaging data over relatively large ROIs. Using the enhanced analysis, CSD events initiated by KCl could be quantified for the first time as primary or secondary according to their spatial and temporal features. Primary events covered 26.2 ± 9.9 mm 2 of cortical surface (mean ± SD, n = 7 experiments) and propagated rapidly (3.5 ± 0.65 mm • min −1 ) with a hemispherical geometry. In contrast, the subsequent secondary events were multiple, spatially restricted (covering 7.6 ± 4.6 mm 2 , P < 0.005), slower in propagation (2.6 ± 0.41 mm • min −1 , P < 0.012), and often confined to the originating gyrus (26 out of 59 events). However, both event types were associated with significantly reduced apparent diffusion coefficients (ADCs; from 800 to ∼660 × 10 −6 mm 2 • s −1 , P < 0.05) that were similar for both primary (21 ± 5.1%) and secondary waves (18 ± 7.7%) and that had similar durations (full width at half‐maximal height: 86 ± 17 vs. 79 ± 20 seconds, respectively). These findings associate CSD for the first time with two categories of ADC disturbance that are similar in amplitude and duration but that differ in spatial extent, velocity, and extensiveness of spread. J. Magn. Reson. Imaging 2000;12:722–733. © 2000 Wiley‐Liss, Inc.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here