z-logo
Premium
Three‐dimensional reconstruction of monoclonal antibody uptake in tumor and calculation of beta dose‐rate nonuniformity
Author(s) -
Roberson Peter L.,
Heidorn Douglas B.,
Kessler Marc L.,
Ten Haken Randall K.,
Buchsbaum Donald J.
Publication year - 1994
Publication title -
cancer
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 3.052
H-Index - 304
eISSN - 1097-0142
pISSN - 0008-543X
DOI - 10.1002/1097-0142(19940201)73:3+<912::aid-cncr2820731325>3.0.co;2-p
Subject(s) - nuclear medicine , convolution (computer science) , histogram , dosimetry , absorbed dose , mathematics , optics , physics , medicine , computer science , image (mathematics) , machine learning , artificial intelligence , artificial neural network
Background . The measurement of the heterogeneity of radiolabeled monoclonal antibody uptake in tumor has an essential role in the calculation and interpretation of the absorbed dose of radiation. Large data arrays and long calculation times have been limiting factors in the calculation of three‐dimensional dose‐rate distributions used to study the relationship between uptake heterogeneity and dose. Methods . Serial autoradiographs of tumor sections were digitized with ∼100 μm resolution using a laser densitometer. The section images were aligned to form a registered tumor‐image data set. The image data were corrected for film response versus activity density to create a three dimensional activity density distribution using features of a three‐dimensional radiotherapy treatment planning system. Dose‐rate distributions were formed by convolution with a beta dose kernel using fast Fourier transforms. Results . Differential dose‐rate‐volume histograms (derived from the dose‐rate distribution) were created to summarize the dose‐rate nonuniformity throughout the tumor volume. Effects of section sampling interval, interpolation methods between section planes, and calculation resolution on the dose‐rate‐volume histograms were illustrated. Conclusions . The several orders of magnitude improvement in calculational speed provided by the fast Fourier transform technique allowed an investigation of the effects of the calculational parameters. This investigation enabled tuning of both data acquisition and dose computation. These studies can lead to further enhancements in the calculational efficiency of three‐dimensional dose‐rate distributions. These improvements will allow the study of summing techniques to yield average total dose distributions. Cancer 1994; 73:912–8.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here