z-logo
Premium
Experimental and clinical results of Er:YAG laser stapedotomy
Author(s) -
Lippert Burkard M.,
Gottschlich Stefan,
Külkens Christoph,
Folz Benedikt J.,
Rudert Heinrich,
Werner Jochen A.
Publication year - 2000
Publication title -
lasers in surgery and medicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.888
H-Index - 112
eISSN - 1096-9101
pISSN - 0196-8092
DOI - 10.1002/1096-9101(2001)28:1<11::aid-lsm1010>3.0.co;2-m
Subject(s) - footplate , stapes , medicine , otosclerosis , perforation , surgery , laser , dissection (medical) , middle ear , materials science , optics , mechanical engineering , physics , engineering , punching , metallurgy
Background and Objective At the beginning of the 1980s, different laser types were used for stapes surgery to reduce potential harm to inner ear structures through manipulation with conventional instruments during stapedotomy. Most clinical studies were carried out with the CO 2 or the argon laser. The Er:YAG laser has been used rarely in patients with otosclerosis. Study Design/Materials and Methods In an experimental study on 54 human petrous bones, the optimal laser energy parameter for dissection of the posterior stapes crus and the footplate perforation were determined. With these parameters, stapedotomy was carried out with the Er:YAG laser in 29 patients with otosclerosis with a conventional dissection of the incudostapedial joint and the stapedius muscle tendon. The Er:YAG laser was used (60 or 100 mJ, 3–6 pulses) for dissection of the posterior stapes crus and footplate perforation. Results No intra‐ or postoperative complications were observed in all 29 patients. Vertigo and hearing loss were not observed intra‐ or postoperatively. The postoperative hearing results (improvement of the air‐bone gap) was in all cases satisfactory (median remaining air bone gap, 8.1 dB). The median operation time was 29 minutes (15–42 minutes) and did not show a significant prolongation in comparison to the conventional technique. In 1 of the 29 patients, the footplate perforation needed to be carried out conventionally. Conclusion For the first time, Er:YAG laser parameters have been optimized and refined in a human petrous bone model and were then used in a clinical setting. According to the presented results, the Er:YAG laser seemed to be a very suitable instrument for stapedotomy. Lasers Surg. Med. 28:11–17, 2001. © 2001 Wiley‐Liss, Inc.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here