Premium
Short‐Term bioeffects of an infrared pulsed laser device on burned rat skin monitored by transverse relaxation times (NMR)
Author(s) -
SantanaBlank Luis A.,
RodríguezSantana Elizabeth,
ScottAlgara Daniel,
Hunger Manfred,
SantanaRodríguez Karin E.,
Orellana Rafael
Publication year - 2000
Publication title -
lasers in surgery and medicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.888
H-Index - 112
eISSN - 1096-9101
pISSN - 0196-8092
DOI - 10.1002/1096-9101(2000)27:5<411::aid-lsm1002>3.0.co;2-p
Subject(s) - irradiation , nuclear magnetic resonance , relaxation (psychology) , chemistry , continuous wave , laser , proton , infrared , nuclear medicine , materials science , medicine , optics , physics , nuclear physics , quantum mechanics
Background and Objective The aim of this study was to determine whether the application of an infrared pulsed laser device (IPLD) on the burned skin of rats induced significant changes in the water dynamics of the burned tissues as measured by nuclear magnetic resonance (NMR) at a proton frequency of 90 MHz by using transverse relaxation times (T 2 , I/T 2 ). Study Design/Materials and Methods Seven groups (GI–GVII), each consisting of four albino rats (Sprague‐Dawley), of 12–14 weeks of age were used in the experiment. Rats in GI–GVI were anesthetized and burned with a hot tip. GI, GIII, GV were not irradiated. GII, GIV, GVI were irradiated at 0 hours; 0 and 24 hours; and 0, 24, and 48 hours, respectively. Rats in GVII served as controls and were neither burned nor irradiated. Samples from all groups were obtained and monitored by NMR by using transverse relaxation times (T 2 and 1/T 2 ). An unpaired Student's t ‐test and a one‐way analysis of variance (ANOVA I) were preformed on the mean values obtained (T 2 , 1/T 2 ). The statistical design was chosen to give a 95% power of contrast 1‐β (1/T 2 ). The modulated beam of the IPLD used is composed of two superposed waves; a carrier wave (3 MHz), and a drive force wave in the near infrared (904 nm, f = 10 14 Hz). A dose of 1.5 × 10 3 J/M 2 per session was applied by placing the IPLD directly over the burned tissue by using a top‐hat distribution. Results The results of a t ‐test on the T 2 and 1/T 2 values did not show statistically significant differences at 0 and 24 hours between the irradiated groups, the nonirradiated groups, and the nonburned nonirradiated (control) group. Nonetheless, at 48 hours after the burn, we found a statistically significant difference in the 1/T 2 values for the irradiated specimens compared with the nonirradiated specimens and the control group. Furthermore, the variance of the 1/T 2 values as a function of time showed a tendency to decrease significantly only for the irradiated specimens. Conclusion These findings show possible effects on the water dynamics of burned rat tissue in a short term as a result of the IPLD's application. Lasers Surg. Med. 27:411–419, 2000. © 2000 Wiley‐Liss, Inc.