z-logo
Premium
The effect of residual Nyquist ghost in quantitative echo‐planar diffusion imaging
Author(s) -
Porter David A.,
Calamante Fernando,
Gadian David G.,
Connelly Alan
Publication year - 1999
Publication title -
magnetic resonance in medicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.696
H-Index - 225
eISSN - 1522-2594
pISSN - 0740-3194
DOI - 10.1002/(sici)1522-2594(199908)42:2<385::aid-mrm21>3.0.co;2-j
Subject(s) - echo planar imaging , residual , diffusion , artifact (error) , nyquist–shannon sampling theorem , imaging phantom , nuclear magnetic resonance , signal (programming language) , single shot , physics , planar , diffusion mri , nyquist frequency , sensitivity (control systems) , computer science , optics , algorithm , magnetic resonance imaging , artificial intelligence , computer vision , medicine , radiology , computer graphics (images) , filter (signal processing) , electronic engineering , programming language , engineering , thermodynamics
Single‐shot diffusion‐weighted echo‐planar imaging (EPI) is typically used for most clinical diffusion studies due to its low sensitivity to patient motion. Although the Nyquist ghost artifact in EPI can be substantially reduced, there is frequently a residual ghost with low signal intensity. As reported in this study, this residual ghost can produce severe artifacts when maps of the apparent diffusion coefficient (ADC) are calculated from single‐shot echo‐planar images. The artifacts presented in this paper appear as regions of apparently low ADC which simulate regions of reduced diffusion, but are in fact generated by b‐value dependent Nyquist ghosts of the orbits. Data acquired in vivo were used to demonstrate that these artifacts can be avoided by including standard methods of spatial presaturation or fluid‐suppression in the diffusion‐weighted EPI protocol. In addition, phantom studies were used to illustrate how phase and amplitude variations in the ghost generate the artifacts and theoretical expressions, derived elsewhere, were used to provide a detailed understanding of the artifacts observed in vivo. The level of Nyquist ghost reported for the current generation of commercial scanners suggests that this is a general phenomenon which should be a consideration in all EPI‐based diffusion studies. Magn Reson Med 42:385–392, 1999. © 1999 Wiley‐Liss, Inc.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here