z-logo
Premium
Cytologic detection of esophageal squamous cell carcinoma and precursor lesions using balloon and sponge samplers in asymptomatic adults in Linxian, China
Author(s) -
Roth Mark J.,
Liu ShuFan,
Dawsey Sanford M.,
Zhou Bin,
Copeland Christie,
Wang GuoQing,
Solomon Diane,
Baker Stuart G.,
Giffen Carol A.,
Taylor Philip R.
Publication year - 1997
Publication title -
cancer
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 3.052
H-Index - 304
eISSN - 1097-0142
pISSN - 0008-543X
DOI - 10.1002/(sici)1097-0142(19971201)80:11<2047::aid-cncr3>3.0.co;2-u
Subject(s) - medicine , asymptomatic , cytology , basal cell , pathology , carcinoma , radiology
BACKGROUND The principal reason for the poor prognosis of esophageal carcinoma is that most tumors are asymptomatic and go undetected until they are unresectable. Previous studies have shown that cytologic screening of asymptomatic high risk individuals can detect curable esophageal carcinomas and precursor lesions, but the sensitivity of such screening is not well documented. The current study evaluated the sensitivity and specificity of currently available balloon and sponge cytologic samplers for detecting biopsy‐proven squamous dysplasia and carcinoma in asymptomatic individuals from a high risk population in Linxian, China. METHODS Asymptomatic adults were examined with both balloon and sponge samplers, in random order, followed by endoscopy with mucosal iodine staining and biopsy of all unstained lesions. The cytology slides were interpreted using the criteria of the Bethesda System. The balloon and sponge cytologic diagnoses (test) were compared with the biopsy diagnosis (truth) in each patient to estimate the sensitivity and specificity of each sampler. RESULTS Of the 439 patients with adequate biopsies, 123 (28%) had histologic squamous dysplasia and 16 (4%) had an invasive squamous carcinoma. The sensitivities/specificities of the balloon and sponge were 44%/99% and 18%/100%, respectively, for detecting biopsy‐proven squamous cell carcinoma, and 47%/81% and 24%/92%, respectively, for identifying squamous dysplasia or carcinoma. CONCLUSIONS In this study, the balloon sampler was more sensitive than the sponge sampler for detecting esophageal squamous disease, but both techniques were less than optimal. Improved samplers and/or cytologic criteria should increase the sensitivities observed in this baseline study. Cancer 1997; 80:2047‐59. © 1997 American Cancer Society.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here