z-logo
Premium
Experiment and validation of numerical simulation of coupled thermal, hydraulic and mechanical behaviour in the engineered buffer materials
Author(s) -
Chijimatsu Masakazu,
Fujita Tomoo,
Kobayashi Akira,
Nakano Masashi
Publication year - 2000
Publication title -
international journal for numerical and analytical methods in geomechanics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.419
H-Index - 91
eISSN - 1096-9853
pISSN - 0363-9061
DOI - 10.1002/(sici)1096-9853(20000410)24:4<403::aid-nag73>3.0.co;2-e
Subject(s) - gravimetric analysis , buffer (optical fiber) , bentonite , geotechnical engineering , materials science , overpressure , pore water pressure , thermal , stress (linguistics) , finite element method , thermal hydraulics , hydraulic conductivity , heat transfer , nuclear engineering , mechanics , environmental science , engineering , structural engineering , chemistry , thermodynamics , telecommunications , linguistics , physics , philosophy , organic chemistry , soil water , soil science
Evaluation of the coupled heat transfer, water flow and stress changes in the engineered clay barrier is an important issue in the performance assessment of the high‐level radioactive waste disposal. To demonstrate the function of the engineered barrier system, the large‐scale experiment is conducted, which is called Big Bentonite facility (BIG‐BEN). The facility consists of an electric heater surrounded by glass beads, carbon steel overpack, buffer material and man‐made rock. The buffer is a mixture of bentonite and sand. The heater is operated at 0·8 kW. Water is injected from the interface between the buffer and the man‐made rocks at the pressure of 0·05 MPa. The duration of the experiment is 20 months. The change in temperature and swelling pressure are continuously monitored and gravimetric water content is measured by sampling. The coupled thermal, hydraulic and mechanical processes are simulated with a finite element code THAMES, which can simulate the fully coupled phenomena in the saturated and unsaturated clay under anisothermal condition. To examine the validity of the code, all the parameters used in the model are evaluated from the other laboratory tests. The simulated results are compared with the measured ones without calibration of the parameter values using the results from the BIG‐BEN experiment. It can be concluded that the changes in temperature and gravimetric water content within the buffer can be simulated reasonably well and that the mechanical effect such as swelling pressure is difficult to realize. Copyright © 2000 John Wiley & Sons, Ltd.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here