Simulated radiation levels and patterns of MRI without a Faraday shielded room
Author(s) -
Kazemivalipour Ehsan,
Guerin Bastien,
Wald Lawrence L.
Publication year - 2025
Publication title -
magnetic resonance in medicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.696
H-Index - 225
eISSN - 1522-2594
pISSN - 0740-3194
DOI - 10.1002/mrm.30499
Subject(s) - shielded cable , physics , electromagnetic coil , radiation , field strength , radius , symmetry (geometry) , magnetic field , computational physics , optics , radiation pattern , nuclear magnetic resonance , acoustics , geometry , antenna (radio) , mathematics , telecommunications , computer science , computer security , quantum mechanics
Abstract Purpose We characterize electromagnetic (EM) radiation patterns and levels in conventional MRI systems as a function of field strength and load symmetry, providing a framework for mitigation strategies allowing operation without a shielded room. Methods We simulated the far‐field radiation pattern and fields at a 10 m radius (|E| 10m and |B| 10m ) for a solenoidal superconducting MRI with a body birdcage coil operated between 0.25T and 6.5T. Five load configurations probed the impact of load‐symmetry, ranging from a sphere to a body load (least‐symmetric). We also assessed simple layered EM absorbers at the bore‐ends. Results All configurations exceeded regulatory limits for realistic transmit levels. At 1.5T, a 300 V rms RF‐pulse is 2700‐fold the |E| 10m limit. Field strength and load symmetry strongly modulate radiation patterns and levels. The radiated power increased by more than four orders of magnitude from 0.25T to 6.5T. Spherical load radiation transitioned from a peak gain at the bore‐ends (0.25–0.5T) to a donut‐shaped pattern, suggesting current loops around the bore (1 T–1.5T), back to bore‐axis‐directed gain, suggesting propagating waves along the bore (2T–6.5T). Transition patterns were seen between these regimes; uniform radiation at 0.75T and a combined donut/bore‐directed pattern at 1.75T. Load asymmetry increased both strength and pattern asymmetry, with the body load having the highest and least symmetric radiation with the legs facilitating wave propagation at high‐fields. A simple optimized layered absorber at scanner's service‐end reduced 3T peak radiation by 11 dB. Conclusion Radiation from unshielded scanners far exceeds regulatory limits, particularly at high‐field. Mitigation strategies must address load‐symmetry, field strength, and wave effects.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom