Quantitative multislice and jointly optimized rapid CEST for in vivo whole‐brain imaging
Author(s) -
Cohen Ouri,
Young Robert J.,
Otazo Ricardo
Publication year - 2025
Publication title -
magnetic resonance in medicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.696
H-Index - 225
eISSN - 1522-2594
pISSN - 0740-3194
DOI - 10.1002/mrm.30488
Subject(s) - multislice , pulse sequence , reproducibility , concordance correlation coefficient , sequence (biology) , nuclear medicine , nuclear magnetic resonance , computer science , mathematics , chemistry , physics , medicine , statistics , biochemistry
Abstract Purpose To develop a quantitative multislice chemical exchange saturation transfer (CEST) schedule optimization and pulse sequence that reduces the loss of sensitivity inherent to multislice sequences. Methods A deep learning framework was developed for simultaneous optimization of scan parameters and slice order. The optimized sequence was tested in numerical simulations against a random schedule and an optimized single‐slice schedule. The scan efficiency of each schedule was quantified. Three healthy subjects were scanned with the proposed sequence. Regions of interest in white matter (WM) and gray matter (GM) were defined. The sequence was compared with the single‐slice sequence in vivo and differences quantified using Bland–Altman plots. Test–retest reproducibility was assessed, and the Lin's concordance correlation coefficient (CCC) was calculated for WM and GM. Intersubject variability was also measured with the CCC. Feasibility of whole‐brain clinical imaging was tested using a multislab acquisition in 1 subject. Results The optimized multislice sequence yielded a lower mean error than the random schedule for all tissue parameters and a lower error than the optimized single‐slice schedule for four of six parameters. The optimized multislice sequence provided the highest scan efficiency. In vivo tissue‐parameter values obtained with the proposed sequence agreed well with those of the optimized single‐slice sequence and prior studies. The average WM/GM CCC was 0.8151/0.7779 for the test–retest scans and 0.7792/0.7191 for the intersubject variability experiment. Conclusion A multislice schedule optimization framework and pulse sequence were demonstrated for quantitative CEST. The proposed approach enables accurate and reproducible whole‐brain quantitative CEST imaging in clinically relevant scan times.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom