z-logo
Premium
Osteoarthritic Human Synovial Fluid Alters CoCrMo Electrochemical Properties on a Patient‐Specific Basis
Author(s) -
Bond Bailey,
Brown Madison N.,
Kurtz Michael A.,
Robinson Alayna,
Mihalko Marc J.,
Crockarell John R.,
Holland Christopher T.,
Guyton James L.,
Mihalko William M.
Publication year - 2025
Publication title -
journal of orthopaedic research®
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.041
H-Index - 155
eISSN - 1554-527X
pISSN - 0736-0266
DOI - 10.1002/jor.26079
ABSTRACT Cobalt‐chromium‐molybdenum (CoCrMo) femoral components are widely used in total knee arthroplasty (TKA). However, recent retrospective clinical trials associate moderate adverse local tissue reactions with CoCrMo release in the knee. Additionally, gaps persist in our understanding of the fundamental corrosion processes that occur at the CoCrMo‐synovial fluid interface. In this study, we investigated the electrochemical behavior of CoCrMo in human synovial fluid obtained at the time of primary TKA, using CoCrMo in phosphate‐buffered saline (PBS) as a comparison. Synovial fluid was collected from 118 patients immediately before arthroplasty, then transferred to a three‐electrode electrochemical cell with a wrought CoCrMo alloy working electrode. To quantify electrochemical properties, open circuit potential (OCP), electrochemical impedance spectroscopy, and linear polarization tests were run. Generally, the properties varied on a patient‐by‐patient basis and significantly differed ( p  < 0.05) from comparison tests performed in PBS. In human synovial fluid, we measured OCPs between a range of −0.38 and 0.15 V and corrosion potentials ( E corr ) between −0.95 and −0.2 V. Additionally, we reported instantaneous corrosion rates (1/ R p ) spanning nearly four orders of magnitude. The variability we documented suggested that the electrochemical properties of CoCrMo implants may depend on the patient's local physiological environment, influenced by the biological and chemical components of synovial fluid. Statement of Clinical Significance: This study shows that human synovial fluid affects the electrochemical behavior of CoCrMo, evidenced by the variation on a patient‐by‐patient basis. This study may have implications for long‐term biological response to orthopaedic implants, including total knee arthroplasty.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here
Empowering knowledge with every search

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom