Needleless Closed System Does Not Reduce Central Venous Catheter-Related Bloodstream Infection: A Retrospective Study
Author(s) -
Mitsuru Ishizuka,
Hitoshi Nagata,
Kazutoshi Takagi,
Keiichi Kubota
Publication year - 2013
Publication title -
international surgery
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.132
H-Index - 39
eISSN - 2520-2456
pISSN - 0020-8868
DOI - 10.9738/cc132.1
Subject(s) - medicine , central venous catheter , bloodstream infection , catheter , retrospective cohort study , surgery
The needleless closed system (NCS) has been disseminated in several clinical fields to prevent central venous catheter–related bloodstream infection (CVC-RBSI), in place of the conventional Luer cap system (LCS). The purpose of this study is to examine whether NCS is really superior to conventional LCS for prevention of CVC-RBSI. Between May 2002 and December 2008, 1767 patients received CVC in our department. The time interval from insertion to development of CVC-RBSI was compared retrospectively between selected patients who were treated using the conventional LCS (group 1, n = 89, before June 2006) and the NCS (group 2, n = 406, June 2006 and after). Kaplan-Meier analysis revealed no significant difference in the time interval from insertion to development of CVC-RBSI between the two groups. NCS does not reduce CVC-RBSI in adult colorectal cancer patients who undergo CVC insertion.