Global fan speed control considering non-ideal temperature measurements in enterprise servers
Author(s) -
Jungsoo Kim,
Mohamed M. Sabry,
David Atienza,
Kalyan Vaidyanathan,
Kenny Gross
Publication year - 2014
Publication title -
2014 design, automation and test in europe conference and exhibition (date)
Language(s) - English
Resource type - Conference proceedings
eISSN - 1558-1101
pISSN - 1530-1591
ISBN - 978-3-9815370-2-4
DOI - 10.7873/date.2014.289
Subject(s) - communication, networking and broadcast technologies , components, circuits, devices and systems , computing and processing
Time lag and quantization in temperature sensors in enterprise servers lead to stability concerns on existing variable fan speed control schemes. Stability challenges become further aggravated when multiple local controllers are running together with the fan control scheme. In this paper, we present a global control scheme which tackles the concerns on the stability of enterprise servers while reducing the performance degradation caused by the variable fan speed control scheme. We first present a stable fan speed control scheme based on the ProportionalIntegral-Derivative (PID) controller by adaptively adjusting the PID parameters according to the operating fan speed and eliminating the fan speed oscillation caused by temperature quantization. Then, we present a global control scheme which coordinates control actions among multiple local controllers. In addition, it guarantees the server stability while minimizing the overall performance degradation. We validated the proposed control scheme using a presently shipping commercial enterprise server. Our experimental results show that the proposed fan control scheme is stable under the non-ideal temperature measurement system (10 sec in time lag and 1°C in quantization figures). Furthermore, the global control scheme enables to run multiple local controllers in a stable manner while reducing the performance degradation up to 19.2% compared to conventional coordination schemes with 19.1% savings in power consumption.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom