z-logo
open-access-imgOpen Access
Development and validation of an analytical method for detection and quantification of benzophenone, bisphenol A, diethyl phthalate and 4-nonylphenol by UPLC-MS/MS in surface water
Author(s) -
Frederico Goytacazes de Araujo,
Glauco F. Bauerfeldt,
Márcia Marques,
Eduardo Monteiro Martins
Publication year - 2020
Publication title -
peerj analytical chemistry
Language(s) - English
Resource type - Journals
ISSN - 2691-6630
DOI - 10.7717/peerj-achem.7
Subject(s) - detection limit , diethyl phthalate , chromatography , chemistry , solid phase extraction , solvent , elution , matrix (chemical analysis) , nonylphenol , dimethyl phthalate , environmental chemistry , phthalate , environmental science , organic chemistry
Guandu River is the main water source for 9 million inhabitants in Rio de Janeiro city and some others included in the metropolitan region of the Rio de Janeiro State, Brazil. Here, the development of a chromatographic method and its application to assess the occurrence of 4-nonylphenol (4NP), benzophenone (BP), bisphenol A (BPA) and diethyl-phthalate (DEP), known as endocrine disruptors (EDs), is reported. Sample were prepared by solid phase extraction (SPE) with C18 cartridge and methanol as elution solvent. Validation of analytical method followed the United States Environmental Protection Agency protocol (USEPA 8000D guide) and selectivity, matrix effect, linearity, precision, accuracy, robustness, limit of detection (LOD) and limit of quantification (LOQ) were evaluated. The recovery was greater than 90%, accuracy was found between 80% and 115% and relative standard deviation (RSD) below 11.03%. LOQ ranged from 10.0 to 50.0 ng L−1, while the LOD ranged from 0.87 to 5.72 ng L−1. The coefficients of determination (R2) were greater than 0.99 for all compounds within a linear ranges of 10.0 to 500 ng L−1 for 4NP and BP and 50.0 to 500 ng L−1 for BPA and DEP. The method was therefore considered selective and robust for all micropollutants. Matrix effect was observed for BP, 4NP and DEP. The developed method was applied to analyze five samples collected monthly during 2018 at a selected sampling point of a river in Rio de Janeiro State. The maximum concentrations found for BPA, BP, DEP and 4NP were 182.04, 286.20, 2.56×103 and 13.48 ng L−1 respectively. These values are high enough to justify an investigation on the presence of these micropollutants in drinking water as well as to extend the monitoring for the search of similar pollutants and their metabolites. Subjects Analytical Chemistry (other), Mass Spectrometry, Separation Science

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom