z-logo
open-access-imgOpen Access
Semi-automated carotid lumen segmentation in computed tomography angiography images
Author(s) -
Reza Hamid,
Mahdi Alizadeh,
Alireza KamaliAsl,
Shirani Shapour
Publication year - 2017
Publication title -
journal of biomedical research
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.617
H-Index - 31
eISSN - 2352-4685
pISSN - 1674-8301
DOI - 10.7555/jbr.31.20160107
Subject(s) - stenosis , lumen (anatomy) , segmentation , medicine , computed tomography angiography , carotid endarterectomy , radiology , angiography , nuclear medicine , artificial intelligence , computer science , surgery
Carotid artery stenosis causes narrowing of carotid lumens and may lead to brain infarction. The purpose of this study was to develop a semi-automated method of segmenting vessel walls, surrounding tissues, and more importantly, the carotid artery lumen by contrast computed tomography angiography (CTA) images and to define the severity of stenosis and present a three-dimensional model of the carotid for visual inspection. In vivo contrast CTA images of 14 patients (7 normal subjects and 7 patients undergoing endarterectomy) were analyzed using a multi-step segmentation algorithm. This method uses graph cut followed by watershed and Hessian based shortest path method in order to extract lumen boundary correctly without being corrupted in the presence of surrounding tissues. Quantitative measurements of the proposed method were compared with those of manual delineation by independent board-certified radiologists. The results were quantitatively evaluated using spatial overlap surface distance indices. A slightly strong match was shown in terms of dice similarity coefficient (DSC) = 0.87±0.08; mean surface distance (D msd ) = 0.32±0.32; root mean squared surface distance (D rmssd ) = 0.49±0.54 and maximum surface distance (D max ) = 2.14±2.08 between manual and automated segmentation of common, internal and external carotid arteries, carotid bifurcation and stenotic artery, respectively. Quantitative measurements showed that the proposed method has high potential to segment the carotid lumen and is robust to the changes of the lumen diameter and the shape of the stenosis area at the bifurcation site. The proposed method for CTA images provides a fast and reliable tool to quantify the severity of carotid artery stenosis.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom