z-logo
open-access-imgOpen Access
A double-primary dead-weight tester for pressures (35-175) kPa in gage mode
Author(s) -
Kiran Jain,
Y. Cen,
Walter J. Bowers,
James W. Schmidt
Publication year - 2003
Publication title -
journal of research of the national institute of standards and technology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.202
H-Index - 59
eISSN - 2165-7254
pISSN - 1044-677X
DOI - 10.6028/jres.108.003
Subject(s) - materials science , mode (computer interface) , nuclear engineering , environmental science , computer science , engineering , operating system
Primary pressure standards in the atmospheric pressure range are often established using mercury manometers. Less frequently, controlled-clearance dead-weight testers in which one component (normally the piston) has been dimensionally measured have also been used. Recent advances in technology on two fronts i) the fabrication of large-diameter pistons and cylinders with good geometry; and ii) the ability to measure the dimensions of these components, have allowed some dead-weight testers at NIST to approach total relative uncertainties (k = 2) in dimensionally-derived effective areas near 5 × 10(-6). This paper describes a single piston/cylinder assembly (NIST-PG201WC/WC) that serves as both a primary gage in which both piston and cylinder are measured dimensionally and a controlled-clearance primary gage (employing the Heydemann-Welch method). Thus it allows some previous assumptions about the modeling of dead-weight testers to be checked. For the gage described in this paper the piston/cylinder clearance obtained from the two analyses have relative differences of 4 × 10(-6) to 7 × 10(-6) over the pressure range 35 kPa to 175 kPa. Some implications of these results will be discussed. From the dimensional characterizations and auxiliary measurements we have determined that the effective area for this gauge at 20 °C is: [Formula: see text]where P is the system pressure and P J is a control pressure. The estimated relative uncertainty in effective area is 8.2 × 10(-6) +1.4 × 10(-11) P/Pa (k = 2). The temperature coefficient for the area was measured and found to be (9.06 ± 0.04) × 10(-6)/K. Thus using the gage at a reference temperature of 23 °C yields an effective area: [Formula: see text]with almost no increase in the uncertainty over that at 20 °C.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom