z-logo
open-access-imgOpen Access
Combined use of Very Low Frequency Electromagnetic (VLF-EM) and electrical resistivity survey for evaluation of groundwater potential of Modomo/Eleweran area, south western Nigeria
Author(s) -
MANICKAM T.S,
Ong M,
Ca G
Publication year - 2016
Publication title -
african journal of environmental science and technology
Language(s) - English
Resource type - Journals
ISSN - 1996-0786
DOI - 10.5897/ajest2015.2040
Subject(s) - vertical electrical sounding , geology , basement , overburden , bedrock , groundwater , geophysics , aquifer , electrical resistivity tomography , depth sounding , geophysical survey , electrical resistivity and conductivity , geomorphology , mining engineering , geotechnical engineering , oceanography , civil engineering , electrical engineering , engineering
Very Low Frequency Electromagnetic (VLF-EM) and electrical resistivity surveys were conducted at Modomo/Eleweran, along Ede-road, south western Nigeria, with a view to delineate the hydrogeophysical characterization of the study area. The area is underlain by the Precambrian Basement Complex rocks. The VLF-EM traverses were established along 6 traverses with a station interval of 10 m with lengths ranging from 130 to 360 m. Linear features presumed to be geologic fissures inferred from the filtered real pseudo-sections helped in selecting twenty-nine VES points that were further probed using ABEM SAS 300 C Resistivity Meter. The spreading were carried out using the convectional Schlumberger electrode configuration with half-current electrode separation (AB/2) varying from 1 to 100 m was used for the sounding. The VES data were presented as depth sounding curves and were appropriately iterated using RESIST version (1.0) software. The VLF filtered real profile displayed a low peak trend depicting poor or no fracture signature. Four lithological formations were delineated which included the topsoil, weathered layer, partly weathered/fractured basement and fresh bedrock. The delineated weathered and fractured basement columns constituted the aquifer units. Additionally, from the geophysical parameters viz a viz thin overburden thickness, clayey weathered layer and low fractured frequency characterized by the study area, it is inferred that the groundwater potential of the area varies between poor and low. However, the study justified the use of a combined geophysical investigation as a better tool in evaluating the groundwater potential in the basement complex.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom