z-logo
open-access-imgOpen Access
Evaluation of a lateral flow device for in-field detection of Banana Xanthomonas Wilt and its application in tracking the systemicity of Xanthomonas campestris pv. musacearum
Author(s) -
Karamura Georgina,
Dennis Ochola,
Smith Julian,
Kubiriba Jerome,
Karamura Eldad
Publication year - 2016
Publication title -
african journal of agricultural research
Language(s) - English
Resource type - Journals
ISSN - 1991-637X
DOI - 10.5897/ajar2016.10966
Subject(s) - xanthomonas campestris , inoculation , xanthomonas , bacterial wilt , biology , horticulture , ralstonia , musaceae , corm , ralstonia solanacearum , microbiology and biotechnology , veterinary medicine , bacteria , medicine , pathogen , genetics
Early detection of Banana Xanthomonas Wilt (BXW) in the field and immediate destruction of infected plants or plant tissue are key control methods to prevent the introduction and spread of BXW. This requires rapid, cost-effective and an on- site diagnostic tool to detect the bacterium, Xanthomonas campestris pv musacearum (Xcm). Polymerase chain reaction (PCR) detection technique for BXW is efficient but requires expensive equipment and knowledgeable expertise; this limits PCR application to the laboratory. This study therefore was carried out to evaluate the enzyme-linked immunosorbent assay (ELISA) tool configured as a lateral flow device (LFD) for detection of Xcm. Studies on the systemicity of Xcm in banana were carried out using the BXW-LFD in a field trial of 300 banana plants of Pisang Awak inoculated with the Xcm at Kiifu Forest, Mukono District, Uganda. Pseudo-stem samples from symptomatic and asymptomatic suckers were collected and tested with the LFD and the results compared with conventional PCR using the GspDm BXW primers. The LFD was able to detect Xcm 3 days post inoculation (dpi), 2 cm above and below inoculation site, 15 to 35 days in the pseudo-stem, 35 to 42 days to reach the corm and 81 days in the lateral roots. The rate of Xcm movement in banana was found to be sigmoid in nature, leveling off as the bacteria moved down the pseudo-stem towards the corm. Conventional PCR was only 24% more sensitive than the LFD. The use of the BXW LFD can therefore boost BXW control measures through improved surveillance and quarantine services to arrest the introduction and spread of the disease within and between national borders.  Key words: Banana Xanthomonas Wilt lateral flow device (BXW LFD), Banana Xanthomonas wilt, Xanthomonas campestris pv musacearum, complete systemicity, incomplete systemicity, lateral flow device.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom