The Impact of Different Permissible Exposure Limits on Hearing Threshold Levels Beyond 25 dBA
Author(s) -
Balachandar S. Sayapathi,
Anselm Ting Su,
David Koh
Publication year - 2014
Publication title -
iranian red crescent medical journal
Language(s) - English
Resource type - Journals
eISSN - 2074-1812
pISSN - 2074-1804
DOI - 10.5812/ircmj.15520
Subject(s) - audiometer , medicine , mcnemar's test , absolute threshold of hearing , hearing loss , noise exposure , hearing protection , noise (video) , audiology , noise induced hearing loss , occupational exposure limit , environmental health , confidence interval , occupational exposure , toxicology , audiometry , statistics , mathematics , artificial intelligence , computer science , image (mathematics) , biology
Development of noise-induced hearing loss is reliant on a few factors such as frequency, intensity, and duration of noise exposure. The occurrence of this occupational malady has doubled from 120 million to 250 million in a decade. Countries such as Malaysia, India, and the US have adopted 90 dBA as the permissible exposure limit. According to the US Occupational Safety and Health Administration (OSHA), the exposure limit for noise is 90 dBA, while that of the US National Institute of Occupational Safety and Health (NIOSH) is 85 dBA for 8 hours of noise exposure.This study aimed to assess the development of hearing threshold levels beyond 25 dBA on adoption of 85 dBA as the permissible exposure limit compared to 90 dBA.This is an intervention study done on two automobile factories. There were 203 employees exposed to noise levels beyond the action level. Hearing protection devices were distributed to reduce noise levels to a level between the permissible exposure limit and action level. The permissible exposure limits were 90 and 85 dBA in factories 1 and 2, respectively, while the action levels were 85 and 80 dBA, respectively. The hearing threshold levels of participants were measured at baseline and at first month of postshift exposure of noise. The outcome was measured by a manual audiometer. McNemar and chi-square tests were used in the statistical analysis.We found that hearing threshold levels of more than 25 dBA has changed significantly from pre-intervention to post-intervention among participants from both factories (3000 Hz for the right ear and 2000 Hz for the left ear). There was a statistically significant association between participants at 3000 Hz on the right ear at 'deteriorated' level ( χ² (1) = 4.08, φ = - 0.142, P = 0.043), whereas there was worsening of hearing threshold beyond 25 dBA among those embraced 90 dBA.The adoption of 85 dBA as the permissible exposure limit has preserved hearing threshold level among participants at 3000 Hz compared to those who embraced 90 dBA.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom