Comparing GlideScope Video Laryngoscope and Macintosh Laryngoscope Regarding Hemodynamic Responses during Orotracheal Intubation: A Randomized Controlled Trial
Author(s) -
Alireza Pournajafian,
Mohammad Reza Ghodraty,
Seyed Hamid Reza Faiz,
Poupak Rahimzadeh,
Hamidreza Goodarzynejad,
Enseyeh Dogmehchi
Publication year - 2014
Publication title -
iranian red crescent medical journal
Language(s) - English
Resource type - Journals
eISSN - 2074-1812
pISSN - 2074-1804
DOI - 10.5812/ircmj.12334
Subject(s) - medicine , orotracheal intubation , laryngoscopy , intubation , anesthesia , hemodynamics , video laryngoscope , elective surgery , haemodynamic response , randomized controlled trial , tracheal intubation , surgery , blood pressure , heart rate
Background: To determine if the GlideScope® videolaryngoscope (GVL) could attenuate the hemodynamic responses to orotracheal intubation compared with conventional Macintosh laryngoscope. Objectives: The aim of this relatively large randomized trial was to compare the hemodynamic stress responses during laryngoscopy and tracheal intubation using GVL versus MCL amongst healthy adult individuals receiving general anesthesia for elective surgeries. Patients and Methods: Ninety five healthy adult patients with American Society of Anesthesiologists physical status class I or II that were scheduled for elective surgery under general anesthesia were randomly allocated to either Macintosh or GlideScope arms. All patients received a standardized protocol of general anesthesia. Hemodynamic changes associated with intubation were recorded before and at 1, 3 and 5 minutes after the intubation. The time taken to perform endotracheal intubation was also noted in both groups. Results: Immediately before laryngoscopy (pre-laryngoscopy), the values of all hemodynamic variables did not differ significantly between the two groups (All P values > 0.05). Blood pressures and HR values changed significantly over time within the groups. Time to intubation was significantly longer in the GlideScope (15.9 ± 6.7 seconds) than in the Macintosh group (7.8 ± 3.7 sec) (P< 0.001). However, there were no significant differences between the two groups in hemodynamic responses at all time points. Conclusions: The longer intubation time using GVL suggests that the benefit of GVL could become apparent if the time taken for orotracheal intubation could be decreased in GlideScope group.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom