Partial Discharges in Ceramic Substrates - Correlation of Electric Field Strength Simulations with Phase Resolved Partial Discharge Measurements
Author(s) -
Christoph Friedrich Bayer,
Uwe Waltrich,
Amal Soueidan,
Eberhard Baer,
Andreas Schletz
Publication year - 2016
Publication title -
transactions of the japan institute of electronics packaging
Language(s) - English
Resource type - Journals
eISSN - 1884-8028
pISSN - 1883-3365
DOI - 10.5104/jiepeng.9.e16-003-1
Subject(s) - electric field , materials science , partial discharge , field strength , ceramic , composite material , phase (matter) , voltage , magnetic field , electrical engineering , chemistry , physics , organic chemistry , quantum mechanics , engineering
High voltages and the edges of the metallization on ceramic substrates (AMB, DBA, DBC, HTCC, LTCC) lead to high electric field strengths. In the vicinity of the metal edges these high electric field strengths induce partial discharges in the ceramic insulation and in the potting and thereby represent one key degradation mechanism of power modules. In this work the correlation of the simulated electric field strength with phase resolved partial discharge (PRPD) measurements has been investigated. For the simulation of the electric field strength a new method was used to bypass numerical artifacts. The simulated values show that it is possible to reduce the electric field strength by an adaption of the metallization structure. There the distance of the upper and the lower metallization to the rim of the ceramic was changed relative to each other. Due to this variation a reduction of the electric field strength of about 30% can be reached by choosing the optimum distance compared to state of the art design. In PRPD measurements for insulating ceramic substrates (AlN/Al2O3 by DCB) we examined whether the electric field strength reduction leads to higher partial discharge inception voltages (PDIV). The measurements were executed on layouts with different dimensions of the upper and lower metallization relative to each other as well as for 3 different thicknesses of the ceramic insulation layer. An increase from 20% to 35% of the PDIV was measured for layouts designed according to the findings from the simulation with respect to electric field strength reduction. Finally, the calculated electric field strength and the measured PDIV were correlated